Related Experiment Video
Updated: Mar 12, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Modifier-assisted differential mobility-tandem mass spectrometry method for detection and quantification of
Pai-Shan Chen1, Shu-Hua Chen2, Jung-Hsuan Chen1
1Department and Graduate Institute of Forensic Medicine, College of Medicine, National Taiwan University, Taiwan; Forensic and Clinical Toxicology Center, National Taiwan University College of Medicine and National Taiwan University Hospital, Taiwan.
Abstract:
An advantage of differential mobility spectrometry (DMS) is it provides an orthogonal mechanism to mass spectrometry (MS). The DMS-MS/MS detects analytes in the gas phase on the basis of differences in ion mobility in low and high electric fields, which makes DMS-MS/MS an alternative to chromatographic separation-MS. One drawback of DMS is its limited resolution and sensitivity, especially for detecting small molecules when using a nonpolar inert gas as the carrier gas. The present work has evaluated the effects on peak capacity of adding chemical modifiers to inert carrier gases (nitrogen, helium, argon and carbon dioxide). Use of a methanol-helium mixture gave improvements in both separation and sensitivity. Nine structurally similar amphetamine-type stimulants were determined in urine without pretreatment of the samples before analysis. After optimization of carrier gas, nature and concentration of chemical modifier, and DMS temperature, limits of detection ranging from 1.1 to 2.7 ng mL-1, with a linear range of three orders of magnitude (5-5000 ng mL-1) were achieved. Precision was <15% and the accuracy of the quality control samples was 87.6-113.7%. For the quantitation of urine samples from drug abusers, data obtained using DMS-MS/MS showed reasonable agreement (within ±19.5%) with that obtained using LC-MS/MS. The analysis time for DMS-MS/MS was only 1.1 min and a paired sample t-test between the two methods gave a p-value of 0.0894, which indicates that DMS-MS/MS is a reliable method, with comparable precision and sensitivity to LC-MS/MS.
More Related Videos
10:13Author Spotlight: An Efficient Methodology to Confidently Differentiate and Characterize Fentanyl Analogs
Published on: November 8, 2024
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
High-Performance Liquid Chromatography: Types of Detectors
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
MALDI-TOF Mass Spectrometry
Mass Analyzers: Common Types