Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The Key to Phaco-Refractive Surgery: Does a Small Incision Make a Big Difference?

Cureus·2026
Same author

Effect of Altitude on Metabolic Syndrome.

Journal of Nepal Health Research Council·2025
Same author

Risk factors of late intraocular Lens displacement: A multi-national study.

European journal of ophthalmology·2025
Same author

Ozanimod-associated macular edema.

Canadian journal of ophthalmology. Journal canadien d'ophtalmologie·2025
Same author

RETROPUPILLARY SULCUS GAS MIGRATION AFTER RETINAL DETACHMENT REPAIR SURGERY.

Retinal cases & brief reports·2024
Same author

Single-triangle technique for congenital ptosis repair with a frontalis sling in blepharophimosis patients.

Taiwan journal of ophthalmology·2022

Related Experiment Video

Updated: Mar 12, 2026

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

2.1K

Modified Krimsky test for irregular scarred corneas.

Harindersingh Sethi1, Mayuresh Naik2,3, Mukesh Joshi1

  • 1Department of Ophthalmology, V.M.M.C & Safdarjung Hospital, Ring Road, Ansari Nagar, New Delhi, 110029, India.

International Ophthalmology
|November 10, 2016
PubMed
Summary

This study presents a modified Krimsky test to accurately measure eye deviation in strabismus patients with irregular corneas. This innovation aids in precise diagnosis and treatment planning for challenging cases.

Keywords:
Cosmetic correction of squintIrregular scarred corneasKrimsky test

More Related Videos

A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1
12:36

A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1

Published on: July 22, 2022

5.1K
Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
10:46

Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty

Published on: September 17, 2014

15.8K

Related Experiment Videos

Last Updated: Mar 12, 2026

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
07:51

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts

Published on: October 21, 2022

2.1K
A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1
12:36

A Human Corneal Organ Culture Model of Descemet's Stripping Only with Accelerated Healing Stimulated by Engineered Fibroblast Growth Factor 1

Published on: July 22, 2022

5.1K
Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty
10:46

Corneal Donor Tissue Preparation for Descemet's Membrane Endothelial Keratoplasty

Published on: September 17, 2014

15.8K

Area of Science:

  • Ophthalmology
  • Strabismus Diagnosis
  • Corneal Pathology

Background:

  • Accurate measurement of eye deviation is crucial for strabismus diagnosis and treatment planning.
  • The standard Krimsky test is limited in patients with corneal opacities, hindering accurate deviation measurement.
  • Difficulties arise in visualizing corneal reflexes due to scarred or irregular corneas.

Purpose of the Study:

  • To present a modified Krimsky test for measuring strabismus deviation.
  • To overcome limitations of the original Krimsky test in patients with irregular or opaque corneas.
  • To improve diagnostic accuracy for strabismus in challenging corneal conditions.

Main Methods:

  • Modification of the original Krimsky test procedure.
  • Application of the modified test in patients with scarred and irregular corneas.
  • Evaluation of the test's efficacy in determining eye deviation.

Main Results:

  • The modified Krimsky test successfully measured eye deviation in patients with irregular opaque corneas.
  • The technique proved effective where the original Krimsky test was not feasible.
  • Improved ability to assess deviation despite poor visibility of corneal reflexes.

Conclusions:

  • The modified Krimsky test is a valuable tool for strabismus assessment in patients with corneal irregularities.
  • This modification expands the utility of the Krimsky test for a wider patient population.