Evaluation of the Corrosion of Five Different Bracket-Archwire Combination: An In-vitro Analysis Using Inductively
Zeinab Behroozi1, Shahla Momeni Danaei2, Ali Reza Sardarian3
1Dept. of Orthodontics, School of Dentistry, Yasuj University of Medical Science, Yasuj, Iran.
Statement Of The Problem:
Stainless steel brackets release metallic ions following the process of corrosion in the oral environment. These released ions have potential adverse effects on health, friction between wire and bracket, staining, strength of brackets. Choosing a bracket with favorable corrosive properties; therefore, should be a goal of every practitioner.
Purpose:
The goal of this study is to compare the amount of corrosion among five different brands of brackets using inductively coupled plasma (ICP) mass spectrometry.
Materials And Method:
Five different brands of brackets (Dentaurum, 3M, Ortho Organizer, Cobas and O.R.G) were chosen and ten brackets were selected from each brand. A piece of stainless steel wire was ligated to each bracket. The bracket-archwire complex was then immersed in artificial saliva. Subsequently, the samples were analyzed using an ICP device and the levels of iron, chromium, nickel, and manganese ions were measured.
Results:
The findings of this study demonstrated that iron was released the most from the tested brackets, followed by nickel. We also found that the Cobas bracket had the most ion release among the tested brackets (p< 0.05), while Ortho Organizer and ORG performed favorably. There was no significant difference between Dentaurum and 3M (p> 0.05).
Conclusion:
Based on the results, Ortho Organizer and ORG brackets are suggested in terms of resistance to corrosion.
More Related Videos
07:24Imaging Corrosion at the Metal-Paint Interface Using Time-of-Flight Secondary Ion Mass Spectrometry
Published on: May 6, 2019
08:46Dose Uptake of Platinum- and Ruthenium-based Compound Exposure in Zebrafish by Inductively Coupled Plasma Mass Spectrometry with Broader Applications
Published on: April 21, 2022
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Interference