Vector analysis investigation of toric intraocular lens with no deviation from the intended axis
Atsushi Kawahara1, Yoshinori Takayanagi2
1Takayanagi Clinic, Kushiro; Sapporo Kato Eye Clinic, Sapporo, Hokkaido, Japan.
Aim:
The aim of this research was to evaluate vector analysis after implantation of toric intraocular lenses (IOLs) without deviation from the intended axis.
Methods:
The study included 18 eyes of 16 patients who underwent cataract surgery with the insertion of a toric implant (AcrySof IQ Toric). The postoperative IOL meridian placement completely corresponded to that planned. Using vector analysis, surgically induced astigmatism (SIA) was derived from the refractive outcome versus the predicted postoperative keratometric astigmatism and was compared with targeted induced astigmatism (TIA). The difference vector (DV) was derived by calculating the vector expression of the remaining astigmatic change.
Results:
The mean postoperative remaining refractive astigmatism of 0.73±0.55 diopters (D) was achieved versus the mean target of 0.44±0.28 D. There was a difference of 0.29 D between the target and achieved values. The mean SIA value was 1.90±0.99 D compared with the mean TIA value of 2.00±0.85 D. The mean DV value was 0.87±0.56 D. The astigmatism correction index (SIA/TIA) was 0.95, which was near the ideal value of 1. The index of success (DV/TIA) was 0.44, which was far from the ideal value of 0.
Conclusion:
The implantation of toric IOLs is an effective, predictable method for astigmatic correction. However, some remaining astigmatism is present even if toric IOLs are placed accurately.
More Related Videos
04:59Author Spotlight: Enhancing Visual Outcomes in Cataract Surgery: A Novel Technique to Prevent Posterior Capsular Opacification Through IOL Rotation
Published on: July 7, 2023
10:49Ocular Kinematics Measured by In Vitro Stimulation of the Cranial Nerves in the Turtle
Published on: June 2, 2018
Related Concept Videos
Vector Components in the Cartesian Coordinate System
Toroids
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in...
Vector Algebra: Method of Components
In many applications, the magnitudes and directions of...
Node Analysis for AC Circuits
To unravel the complexities of this system, nodal analysis is employed, a powerful technique founded on Kirchhoff's current law (KCL), which remains valid for phasors. AC circuits can effectively be...
Thin-Walled Hollow Shafts
Two-Dimensional Force System