Related Experiment Video
Updated: Mar 12, 2026

Coordinate Mapping of Hyolaryngeal Mechanics in Swallowing
Published on: May 6, 2014
Can parameters of the helical axis be measured reliably during active cervical movements?
Marco Barbero1, Deborah Falla2, Ron Clijsen3
1Rehabilitation Research Laboratory 2rLab, Department of Business Economics, Health and Social Care, University of Applied Sciences and Arts of Southern Switzerland, Manno, Switzerland.
Abstract:
Convex hull area (CHA) and mean angle (MA) have been proposed to describe the behaviour of the helical axis during joint kinematics. This study investigates the intra- and inter-session reliability of CHA and MA during active movements of the cervical spine. Twenty-seven healthy volunteers (19 women) aged 23 ± 2.8 years participated. Each volunteer was tested on two sessions. All participants were instructed to perform the following active movements of the cervical spine: rotation, flexion/extension and lateral bending, each performed to full range and repeated ten consecutive times. Cervical movements were registered with an electromagnetic tracking system. For each participant, each movement and each session, range of motion (ROM), CHA and MA were extracted. ROM showed high intra- and inter-session reliability during all cervical spine movements using this method. Overall, the intra- and inter-session reliability of the helical axis parameters varied depending on the movement direction and ranged from fair to almost perfect. The intra- and inter-session reliability of CHA and MA were almost perfect during rotation whereas the intra- and inter-session reliability of CHA was substantial during lateral bending and intra- and inter-session reliability of MA ranged from fair to substantial during flexion/extension and lateral bending. This is the first study to evaluate the reliability of helical axis measures during active movements of the cervical spine. The results show that CHA and MA are promising descriptors of cervical kinematics which could be applied in future studies to evaluate neck function in patients with cervical spine disorders.
Related Concept Videos
Unsymmetric Bending - Angle of Neutral Axis
When a bending moment is applied at an angle θ concerning the vertical axis of a symmetrical member, it can be resolved into components along the member's principal...
Eccentric Axial Loading in a Plane of Symmetry
Angle of Twist - Elastic Range
Articulations of the Vertebral Column
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Mechanism of Ciliary Motion
The cilia are made up of microtubules in a 9+2 arrangement, with nine microtubule doublet ring bundles, surrounding a pair of central singlet microtubule bundles. The doublet microtubule bundles are...

