Related Experiment Video
Updated: Mar 12, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
The effect of additional aeration of liquid on the atomization process for a pneumatic nebulizer
1Faculty of Chemical Technology, Poznan University of Technology, 4 Berdychowo Street, 60-965 Poznan, Poland.
Abstract:
At this paper the effect of aeration on the droplet size distribution of the aerosol have been analyzed. The atomization process was carried out using a pneumatic nebulizer which was equipped with a modified nebulizer cup. This modified nebulizer cup was combined with an additional source of gas bubbles. The measurements of the droplet sizes obtained by the use of the digital microphotography method and analyzed by Image-Pro Plus software. The analysis of the experimental studies proved that an increase in the flow rates of additional gas leads to the increase in the number of small droplets and the decrease of the number of drops of large diameter. Additionally, the mean droplet diameter decreases with the increase of the flow rate of aeration gas. A correlation equation was proposed, which describes the relationship between the mean diameter of droplet and the volumetric flow rate of additional gas. The increase in the bubble volume discharging through a single orifice causes the increase of the flow rate of aeration gas. The modifications of construction of atomizer lead to the better effectiveness of nebulization.
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Inhaled Medications
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...

