Related Experiment Video For Clear cell renal cell carcinoma
Updated: Mar 12, 2026

In Vivo, Percutaneous, Needle Based, Optical Coherence Tomography of Renal Masses
Published on: March 30, 2015
Quantitative iodine content threshold for discrimination of renal cell carcinomas using rapid kV-switching
Jessica G Zarzour1, Desmin Milner2, Roberto Valentin2
1Department of Radiology, University of Alabama at Birmingham, 619 19th Street South, JTN 357, Birmingham, AL, 35294, USA. jgzarzour@uabmc.edu.
Purpose:
Determine iodine content threshold discriminating papillary renal cell carcinomas (pRCC) from complex cysts (CCs) using rapid kV-switching dual-energy CT (rsDECT).
Materials And Methods:
IRB-approved retrospective study of 72 consecutive patients with pathologic diagnosis of renal cell carcinoma, who underwent rsDECT from 2011 to 2015. Controls included consecutive patients with CC during same period. Iodine content of each pRCC (n = 27) was measured on rsDECT workstation for arterial (n = 15) or nephrographic phase (n = 12), and compared to iodine content for clear cell renal cell carcinomas (ccRCC, n = 46) and complex cysts (n = 54). An optimal iodine content threshold was estimated using logistic regressions and Youden's J based on maximum specificity and sensitivity.
Results:
Iodine threshold of 1.28 mg/cc was optimal to discriminate between pRCCs and CCs for nephrographic phase (sens 1.0, spec 0.96, PPV 0.92, and NPV 1.0, AUC 0.997, acc 0.97, p < 0.0001). Iodine threshold of 1.22 mg/cc was the optimal cutoff value to discriminate between pRCCs and CCs in the arterial phase (sens 0.67, spec 0.97, PPV 0.91, NPV 0.85, AUC 0.76, and acc 0.84, p = 0.006). The optimal threshold to discriminate between ccRCCs and pRCCs was 1.85 mg/cc in the arterial phase (sens 0.87, spec 0.92, PPV 0.87, NPV 0.92, p < 0001) and 2.71 mg/cc in the nephrographic phase (sens 1.0, spec 1.0, PPV 1.0, NPV 1.0, p < 0.0001).
Conclusions:
Quantitative iodine values on rsDECT discriminate between papillary RCC and complex cysts, and between papillary RCC and clear cell RCC, the former addressing an important clinical challenge particularly when an unenhanced series has not been performed. These rsDECT thresholds differ from values derived from dual-source DECT technology.
More Related Videos
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT