Related Experiment Video
Updated: Mar 12, 2026

Multimodality Diagnosis of Mesenteric Ischemia
Published on: July 21, 2023
Magnetic resonance evaluation for small bowel strictures in Crohn's disease: comparison with balloon enteroscopy
Kento Takenaka1, Kazuo Ohtsuka1, Yoshio Kitazume2
1Department of Gastroenterology and Hepatology, Internal Medicine, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8519, Japan.
Background:
Magnetic resonance (MR) imaging is the recommended technique for detection of small bowel lesions in Crohn's disease. We aimed to evaluate the impact of stricture findings obtained by MR imaging on patient outcomes using balloon-assisted enteroscopy (BAE) as a reference.
Methods:
Two hundred Crohn's disease patients undergoing both MR enterocolonography and BAE were prospectively followed up for at least 1 year. The presence of strictures detected by MR enterocolonography was compared with endoscopic findings. Moreover, the relationship between MR findings and surgery was evaluated.
Results:
The accuracy of MR imaging for detection of small bowel strictures was defined by a sensitivity of 60.6% and a specificity of 93.4%. Major strictures (diameter less than 10 mm or with internal fistula), long strictures (length 10 mm or greater), and prestenotic dilatation were predictors of stricture detection by MR imaging (P = 0.001, 0.017, and 0.002 respectively). Surgery was performed in 31.6% of patients (18 of 57) in the MR-positive-BAE-positive stricture group and in 10.8% of patients (4 of 37) in the MR-negative-BAE-positive stricture group. Multiple regression analysis showed MR-positive-BAE-positive strictures were an independent risk factor for surgery (P = 0.002 at 6 months and P < 0.001 at 1 year). The surgery-free rate in the MR-negative-BAE-positive stricture group was significantly lower than that in nonstricture group at 1 year (P = 0.001).
Conclusions:
The specificity of MR imaging for detection of small bowel strictures was clinically sufficient, and the MR procedure could detect critical strictures, which was a predictive factor for surgery. But MR-negative-BAE-positive strictures were also associated with an increased risk compared with no strictures after 1 year of follow-up.
More Related Videos
12:18Magnetic Resonance Elastography Methodology for the Evaluation of Tissue Engineered Construct Growth
Published on: February 9, 2012
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...
Endoscopic Procedures V: ERCP
Patient...
Magnetic Resonance Imaging
Inflammatory Bowel Disease III: Diagnostic Studies and Management I-Nutritional Therapy
Diagnostic studies
A colonoscopy is the definitive screening test, distinguishing ulcerative colitis from other colon diseases with similar symptoms. During a colonoscopy test, inflamed mucosa with exudate ulcerations can be observed, and biopsies are taken to determine the histologic characteristics of the...
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...