Related Experiment Video
Updated: Mar 12, 2026

Optimization of Transesophageal Atrial Pacing to Assess Atrial Fibrillation Susceptibility in Mice
Published on: June 29, 2022
[Left ventricular synchrony with septum stimulation vs. septal ventricular outflow tract in complete atrioventricular
Gustavo Rodríguez-Serrano1, Susano Lara-Vaca, Texar Pereyra-Nobara
1Hospital de Especialidades 1, Centro Médico Nacional Bajío, Instituto Mexicano del Seguro Social, León, Guanajuato, México. enriquebernalmd@yahoo.com.mx.
Background:
Placing the right ventricular pacing electrode in different places than the apex is less deleterious to the ejection fraction and left ventricular synchrony. Currently it is not defined which non apical site is better alternative. The aim of this paper was to determine if there is a difference in systolic function and left ventricular synchrony with stimulation of medial septum or outflow tract of the right ventricle in patients with atrioventricular block and pacemaker device.
Methods:
This was an observational analytical cross study. The patients included in this study were the population over 18 years old, diagnosed with atrioventricular block and pacemaker device. Two groups were divided according to the site of electrode placement whether in medial septum region or outflow tract of the right ventricle. The ejection fraction and left ventricular synchrony was determined by echocardiogram.
Results:
54 patients were included in each group, with similar demographic characteristics, except for the time of placement of ventricular electrode (p = < 0.001). No significant difference in ejection fraction or left ventricular synchrony was found.
Conclusions:
There were no differences in ejection fraction or left ventricular synchrony regardless of the ventricular electrode placement.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
The Cardiac Cycle
The Process
Electrical signals—sent from the sinoatrial (SA) node in the right atrial wall to the atrioventricular (AV) node between the right atrium and right ventricle—cause both atria to simultaneously contract. When the signal reaches the AV node, it pauses for approximately a tenth of a second, allowing the atria to contract and...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Electrophysiology of Normal Cardiac Rhythm
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...