Safety of bailout stenting after paclitaxel-coated balloon angioplasty
K H Mok1, U Wickramarachchi2, T Watson3,4
1Department of Cardiology, Tan Tock Seng Hospital, 11 Jalan Tan Tock Seng, 308433, Singapore, Singapore.
Background:
Bailout stenting after suboptimal paclitaxel-coated balloon (PCB) angioplasty is required in up to 28% of cases. We sought to compare the safety of bailout stenting with drug-eluting stents (DES) compared with the more established combination of PCB with bare metal stents (BMS).
Methods:
We retrospectively evaluated all patients who had stents implanted owing to suboptimal PCB angioplasty results between January 2010 and April 2015. Endpoints analyzed were major adverse cardiac events (MACE) - defined as cardiovascular death, nonfatal myocardial infarction (MI), and target lesion revascularization (TLR) - as well as major and minor bleeding.
Results:
Baseline clinical characteristics were comparable with a high proportion of diabetics in both groups (50.0% vs. 45.8%, p = 0.74). BMS and DES sizes were similar (mean diameter 2.72 ± 0.50 mm vs. 2.89 ± 0.56 mm, p = 0.20, length 25.22 ± 13.47 mm vs. 28.08 ± 9.08 mm, p = 0.47). Outcomes were comparable at the end of 1 year (MACE 12.2% vs. 9.5%, p = 1.00, TLR 6.1% vs. 4.8%, p = 1.00, MI 0% vs. 4.8%, p = 0.30). There was no case of stent thrombosis or major bleeding, and the rates of minor bleeding were similar (4.2% vs. 4.8%, p = 1.00).
Conclusion:
Our initial experience using DES instead of BMS as a bailout after suboptimal PCB results shows that the procedure is safe and effective at 1 year.