Related Experiment Video
Updated: Mar 11, 2026

Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
Tympanic temperature versus temporal temperature in patients with pyrexia and chills
Wen-Chieh Yang1, Huang-Tsung Kuo, Ching-Hsiao Lin
1Department of Pediatric Emergency Medicine, Changhua Christian Children's Hospital, Changhua School of Medicine, Kaohsiung Medical University, Kaohsiung School of Medicine, China Medical University Department of Developmental and Behavioral Pediatrics, Children's Hospital, China Medical University Department of Thoracic Surgery, Chung-Shan Medical University Hospital Institute of Medicine, Chung-Shan Medical University School of Chinese Medicine, China Medical University Department of Hemato-oncology, Children's Hospital, China Medical University Hospital Laboratory of Epidemiology and Biostastics, Children's Hospital Division of Pediatric General Medicine, Department of Pediatrics, Chang Gung Memorial Hospital at Linko, Kweishan College of Medicine, Chang Gung University, Taoyuan, Taiwan.
Abstract:
Accurate body temperature (BT) measurement is critical for immediate and correct estimation of core BT; measurement of changes in BT can provide physicians the initial information for selecting appropriate diagnostic approach and may prevent unnecessary diagnostic investigation. This study aimed to assess differences in tympanic and temporal temperatures among patients with fever in different conditions, especially in those with and without chills. This prospective study included patients from the emergency department between 2011 and 2012. All temperature measurements were obtained using tympanic thermometers and infrared skin thermometers. Differences in tympanic and temporal temperatures were analyzed according to 6 age groups, 5 ambient temperature groups, and 6 tympanic and temporal temperature subgroups. General linear model analysis and receiver operating characteristic curve analysis were used to estimate the differences in mean tympanic and temporal temperatures. Of the 710 patients enrolled, 246 had tympanic temperature more than 38.0°C, including 46 with chills (18.7%). Fourteen patients (3.0%) had chills and tympanic temperature less than 38°C. In the tympanic temperature subgroup of 39.0 to less than 39.5°C, approximately one-third of the patients had chills (32.3%). In the tympanic temperature subgroup of 38.0 to less than 39.0°C, the tympanic temperature was 0.4°C higher than the temporal temperature in patients without chills and 0.9°C higher in patients with chills. In the tympanic temperature subgroup of 39.0°C or more, tympanic temperature was 0.7°C higher than temporal temperature in patients without chills and 0.8°C higher in patients with chills. Temporal thermometer is more reliable in the age group of less than 1 year and 18 to less than 65 years. When the patients show tympanic temperature range of 38.0 to less than 39.0°C, 0.4°C should be added for patients without chills and 0.9°C for patients with chills to obtain core temperature. However, in patients with tympanic temperature of 39.0°C or more, 0.7°C to 0.8°C should be added, regardless of the presence of chills.
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Increased Body Temperature
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...