Citrate-Buffered Dialysis Solution (Citrasate) Allows Avoidance of Anticoagulation During Intermittent

Pavlina Richtrova1,2, Jan Mares1,2, Lukas Kielberger1,2

  • 1Department of Internal Medicine I, Charles University Medical School and Teaching Hospital, Plzen, Czech Republic.

Artificial Organs
|November 19, 2016
PubMed

Reportedly, citrate-based dialysis solution enables heparin dose tapering or even complete exclusion, particularly in postdilution hemodiafiltration (HDF). The aim of the study was to verify this strategy in predilution setting and to assess its short-term safety, efficacy, and biocompatibility. Ten regular hemodialysis patients were assigned to predilution HDF on acetate- and citrate-based dialysis solutions (0.8 mmol/l trisodium citrate) at random order. Acetate HDF was performed using routine dose of heparin while citrate HDF was heparin free. Plasma calcium, thrombin-antithrombin complexes (TAT), and citrate levels were measured at 0, 30, 60, 120, and 240 min. Following each session, a semiquantitative dialyzer clotting score (DCT 1-5) was assessed and HDF adequacy was determined as spKt/V. Statistical relevance was tested by ANOVA with pP < 0.05 held significant, data are given as means ± standard deviations. All sessions were accomplished successfully, premature termination or circuit re-setting was not necessary. However, DCT was significantly higher in citrate-HDF compared to acetate-HDF regimen (3.4 ± 0.65 and 1.8 ± 0.79, respectively, P = 0.002) as well as TAT generation rate (increase per session by factor 11.0 ± 8.43 and 2.1 ± 1.26, respectively, P = 0.004 between regimens). Ionized calcium declined only by the end of citrate-HDF (from 1.09 ± 0.086 to 0.99 ± 0.030 mmol/L, P = 0.002) yet without accompanying clinical symptoms. Systemic citrate levels increased along the citrate-HDF session but stayed an order of magnitude below concentrations needed to establish citrate anticoagulation (peak at 0.276 ± 0.112 mmol/L). Dialysis adequacy estimated by spKt/V was found lower in citrate-HDF vs. acetate-HDF (1.48 ± 0.163 and 1.58 ± 0.165, respectively, P = 0.006). Although predilution HDF using citrate-based dialysate is feasible without heparin, both dialysis adequacy and biocompatibility is significantly compromised. Therefore, this approach can be adopted for a single procedure but is not acceptable on a regular basis.

Related Concept Videos

Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
2.0K
Dialysis01:27

Dialysis

Renal failure occurs when the kidneys lose their ability to filter waste products from the blood effectively. It can be classified into two types: acute renal failure (ARF) and chronic renal failure (CRF).
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
1.7K
Hemodialysis I: Introduction01:25

Hemodialysis I: Introduction

Hemodialysis (HD) is a medical treatment that artificially removes waste products, excess fluids, and toxins from the blood when the kidneys are no longer able to perform these functions effectively. In this process, blood is filtered through a semipermeable membrane, allowing for the selective removal of waste while preserving necessary components like blood cells and proteins. Hemodialysis is typically performed in patients with end-stage renal disease (ESRD) or severe kidney...
2.6K
Peritoneal Dialysis I: Introduction and Procedure01:30

Peritoneal Dialysis I: Introduction and Procedure

Peritoneal dialysis (PD) is a procedure that facilitates the exchange of solutes, waste products, electrolytes, and excess fluid between the blood in the peritoneal capillaries and a dialysis solution introduced into the peritoneal cavity.Principles of Peritoneal Dialysis (PD)Diffusion: Waste products such as urea and electrolytes move from high concentrations in the blood to low concentrations in the dialysate across the peritoneal membrane. This mechanism is driven by the concentration...
5.0K
Hemodialysis II: Procedure and Complications01:24

Hemodialysis II: Procedure and Complications

DialyzersA hemodialysis (HD) dialyzer is a plastic cartridge containing thousands of parallel hollow fibers, which serve as semipermeable membranes. These fibers are typically made from cellulose-based or other synthetic materials. During HD, blood is pumped into the top of the cartridge and distributed among these fibers. Simultaneously, dialysis fluid, known as dialysate, is introduced into the bottom of the cartridge, bathing the outside of the fibers. Across the semipermeable membrane,...
1.4K
Continuous Renal Replacement Therapy01:30

Continuous Renal Replacement Therapy

Continuous Renal Replacement Therapy, also known as CRRT, is a procedural treatment for acute kidney injury (AKI) that gradually removes uremic toxins and fluids while maintaining acid-base balance and stabilizing electrolytes. It is particularly useful for hemodynamically unstable patients. Unlike intermittent hemodialysis, which is faster, CRRT provides a gentler approach over 24 hours, closely mimicking the function of natural kidneys. However, CRRT is not ideal for patients with...
1.5K