Related Experiment Video
Updated: Mar 11, 2026

Combined Near-infrared Fluorescent Imaging and Micro-computed Tomography for Directly Visualizing Cerebral Thromboemboli
Published on: September 25, 2016
Improved Delineation of Pulmonary Embolism and Venous Thrombosis Through Frequency Selective Nonlinear Blending in
Malte Niklas Bongers1, Georg Bier, Christopher Kloth
1From the Departments of *Diagnostic and Interventional Radiology, and †Diagnostic and Interventional Neuroradiology, University Hospital of Tübingen, Tübingen, Germany; and ‡Johns Hopkins University School of Medicine, Russell H. Morgan Department of Radiology and Radiological Science, Baltimore, MD.
Objective:
The aim of this study was to test the hypothesis that a novel frequency selective nonlinear blending (NLB) algorithm increases the delineation of pulmonary embolism and venous thrombosis in portal-venous phase whole-body staging computed tomography (CT).
Materials And Methods:
A cohort of 67 patients with incidental pulmonary embolism and/or venous thrombosis in contrast-enhanced oncological staging CT were retrospectively selected. Computed tomography data sets were acquired 65 to 90 seconds after intravenous iodine contrast administration using state-of-the-art multi-detector CT scanners. A novel frequency selective NLB postprocessing technique was applied to reconstructed standard CT images. Two readers determined the most suitable settings to increase the delineation of pulmonary embolism and venous thrombosis. Outcome measure included region of interest and contrast-to-noise ratio (CNR) analyses, image noise, overall image quality, subjective delineation, as well as number and size of emboli and thrombi. Statistical testing included quantitative comparisons of Hounsfield units of thrombus and vessel, image noise and related CNR values and subjective image analyses of image noise, image quality and thrombus delineation, number and size in standard, and NLB images.
Results:
Using frequency selective NLB settings with a center of 100 HU, delta of 40 HU, and a slope of 5, CNR values of pulmonary embolism (StandardCNR, 10 [6, 16]; NLBCNR, 22 [15, 30]; P < 0.001) and venous thrombosis (StandardCNR, 8 [5, 15]; NLBCNR, 12 [7, 19]; P = 0.0007) increased. Mean vascular enhancement using NLB was significantly higher than in standard images for pulmonary arteries (Standard, 138 [118, 191] HU; NLB, 269 [176, 329] HU; P < 0.0001) and veins (Standard, 120 [103, 162] HU; NLB, 169 [132, 217] HU; P < 0.0001), respectively. Image noise was not significantly different between standard and NLB images (P = 0.64-0.88). There was substantial to almost perfect interrater agreement as well as a significant increase of overall image quality (P < 0.004) and subjective delineation of the thrombotic material (P < 0.0001) in both subgroups. Nonlinear blending images revealed 8 additional segmental and 13 subsegmental emboli. Thrombus sizes were not significantly different, but subjective accuracy of the measurement could be significantly increased using NLB (P = 0.03).
Conclusions:
Postprocessing of standard whole-body staging CT images with frequency selective NLB improves image quality and the delineation of pulmonary embolism and venous thrombosis.
More Related Videos
10:26A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...