Related Experiment Video
Updated: Mar 11, 2026

Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Comparison of radiation exposure during transradial diagnostic coronary angiography with single- or multi-catheters
Guillaume Plourde1, Eltigani Abdelaal1, Jimmy MacHaalany1
1Quebec Heart-Lung Institute, Laval University, Quebec City, Quebec, Canada.
Objective:
To compare radiation exposure during transradial diagnostic coronary angiography (DCA) using standard single- or multi-catheters with different shapes.
Background:
Transradial DCA can be performed using single- or multi-catheters to canulate left and right coronary ostia. To date, it remains unknown whether there are differences in radiation exposure between the two strategies.
Methods:
From November 2012 to June 2014, 3,410 consecutive patients who underwent transradial DCA were recruited. Groups were based on the initial diagnostic catheter used and were dichotomized between single- and multi-catheters approach. All crossovers were excluded. The multi-catheters approach (Multi) group consisted of Judkins left and right catheters, whereas the single-catheter (Single) group included Amplatz, Barbeau, or Multipurpose catheters. Fluoroscopy time (FT) as a surrogate end-point for total radiation exposure and kerma-area product (KAP; patient radiation exposure) were collected as radiation exposure parameters.
Results:
A single-catheter strategy was used in 439 patients, while 2,971 patients had a multi-catheters approach. There was no significant difference in FT between groups (2.86 ± 1.48 min for Multi vs. 2.87 ± 1.72 min for Single, P = 0.13). The multi-catheters approach was associated with a significant 15% reduction in KAP (3,599 ± 2,214 cGy · cm2 vs. 3,073 ± 1,785 cGy · cm2 , P < 0.0001) compared to the single-catheter approach. When pooling all patients, mean FT was 2.86 ± 1.51 min. Mean KAP was 3,141 ± 1,854 cGy · cm2 . Reference levels in our institution in both groups were below international diagnostic reference levels. Overall both FT and KAP decreased by 15% and 19%, respectively, over the 2-year study period.
Conclusions:
Compared to a single-catheter approach, a multi-catheters approach with standard Judkins catheters for DCA significantly reduced patient radiation exposure. Whether single catheter designed for DCA by radial approach can further reduce radiation exposure compared to Judkins catheters remains to be compared in randomized studies. © 2016 Wiley Periodicals, Inc.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Cardiac Catheterization III: Left Heart Catheterization
Imaging Studies VII: Vascular Imaging