Related Experiment Video
Updated: Mar 11, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Analysis of a Low Dose Protocol to Reduce Patient Radiation Exposure During Percutaneous Coronary Interventions
Davide Maccagni1, Cosmo Godino2, Azeem Latib3
1Cardio-Thoracic-Vascular Department, San Raffaele Hospital, Milan, Italy; Italian Association of Interventional Radiographers (AITRI), Milan, Italy.
Abstract:
The cardiac catheterization laboratory is an important source of radiation for patients and operators and it is good practice to limit exposure as much as possible. The purpose of this study was to evaluate the effectiveness and impact of a radiological low dose protocol (LDP) in terms of reduction in patient radiation exposure during percutaneous coronary interventions (PCIs). From November 2014 to October 2015, 906 consecutive patients who underwent PCI were evaluated. Of these, 571 patients (63%) were treated with the standard dose protocol (SDP) of 15 frames per second for cine acquisition and standard settings for fluoroscopy, and 335 patients (37%) with the LDP of 7.5 frames per second for cine acquisition and low-dose settings for fluoroscopy. In the LDP group, we observed a significant reduction of kerma area product (53.3 LDP vs 115 SDP Gycm2, p <0.0001) and air kerma at interventional reference point (0.79 LDP vs 1.976 SDP Gy, p <0.0001). Marked differences were observed regarding the exceeding of International Commission on Radiological Protection and National Council on Radiation Protection and Measurements' air kerma at interventional reference point trigger level (cutoff for potential skin injuries), which were significantly lower in the LDP group (1.8% vs 7.2%, p <0.0001). Such difference was more relevant in complex PCI. In conclusion, the implementation of LDP allowed a marked reduction in patient dosimetric parameters for PCI and significantly reduced the risk of exceeding the International Commission on Radiological Protection/National Council on Radiation Protection and Measurements trigger levels for potential skin injuries.
More Related Videos
10:28Interventional Diagnostic Procedure: A Practical Guide for the Assessment of Coronary Vascular Function
Published on: March 15, 2022
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Cardiac Catheterization I: Pre-Procedure Overview
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization IV: Nursing Management