CT Angiography: Post-processed Contrast Enhancement for Improved Detection of Pulmonary Embolism
Daniela Muenzel1, Alexander A Fingerle1, Tina Zahel1
1Department of Radiology, Technische Universität München, Ismaningerstr. 22, 81675 Munich, Germany.
Insights
A new post-processing tool, vContrast, significantly improves contrast-to-noise ratio in suboptimal computed tomography angiography (CTA) scans. This enhances pulmonary embolism detection and may reduce iodine contrast material usage.
Area of Science:
- Radiology
- Medical Imaging
- Cardiovascular Imaging
Background:
- Pulmonary embolism (PE) detection relies on computed tomography angiography (CTA).
- Suboptimal contrast enhancement in CTA can hinder accurate PE diagnosis.
- Improving image quality in suboptimal CTA is crucial for diagnostic confidence.
Purpose of the Study:
- To evaluate the efficacy of a post-processing tool (vContrast) in enhancing suboptimal contrast enhancement in CTA.
- To assess the impact of vContrast on image quality metrics, including contrast-to-noise ratio (CNR) and image noise.
- To determine if vContrast improves diagnostic confidence in evaluating pulmonary arteries.
Main Methods:
- Retrospective analysis of 41 patient CT examinations with suboptimal contrast enhancement.
- Application of the vContrast post-processing tool to enhance image contrast.
- Quantitative assessment of CNR and image noise in predefined regions.
- Subjective evaluation of diagnostic image quality by three experienced radiologists.
Main Results:
- vContrast significantly improved CNR by a factor of 1.7 (P < 0.01).
- No increase in image artifacts or significant changes in Hounsfield units for surrounding tissues were observed.
- Radiologists reported significant improvements in diagnostic confidence and image quality.
Conclusions:
- vContrast effectively enhances image quality in suboptimal CTA, making scans diagnostically valuable.
- The tool improves visualization of pulmonary arteries, aiding in PE detection.
- vContrast may allow for a reduction in iodine contrast material dosage.
Rationale And Objectives:
The study aimed to improve the detection of pulmonary embolism via an iodine contrast enhancement tool in patients who underwent suboptimal enhanced computed tomography angiography (CTA).
Materials And Methods:
We evaluated the CT examinations of 41 patients who underwent CTA for evaluation of the pulmonary arteries which suffered from suboptimal contrast enhancement. The contrast enhancement of the reconstructed images was increased via a post-processing tool (vContrast). Image noise and contrast-to-noise ratio (CNR) were assessed in eight different regions: main pulmonary artery, right and left pulmonary arteries, right and left segment arteries, muscle, subcutaneous fat, and bone. For subjective image assessment, three experienced radiologists evaluated the diagnostic quality.
Results:
While employing the post-processing algorithm, the CNR for contrast-filled lumen and thrombus/muscle improves significantly by a factor of 1.7 (CNR without vContrast = 8.48 ± 6.79/CNR with vContrast = 14.46 ± 5.29) (P <0.01). No strengthening of artifacts occurred, and the mean Hounsfield unit values of the muscle, subcutaneous fat, and the bone showed no significant changes. Subjective image analysis illustrated a significant improvement using post-processing for clinically relevant criteria such as diagnostic confidence.
Conclusions:
vContrast makes CT angiograms with inadequate contrast applicable for diagnostic evaluation, offering an improved visualization of the pulmonary arteries. In addition, vContrast can help in the significant reduction of the iodine contrast material.
More Related Videos
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Cardiac Catheterization I: Pre-Procedure Overview
Acute Coronary Syndrome III: Diagnostic Studies