Method to determine the true modulation ratio for comprehensive two-dimensional gas chromatography
David K Pinkerton1, Brendon A Parsons1, Robert E Synovec1
1Department of Chemistry, Box 351700, University of Washington, Seattle, WA, 98195, USA.
Abstract:
A new method is presented to determine the true modulation ratio, MR, from the measurable effective modulation ratio, MR*, in comprehensive two-dimensional gas chromatography, GC×GC, without the requirement for a detector at the end of the primary column. The method was developed through the investigation of modulator induced band broadening, as a function of 1Wb and the selected modulation period, PM, for simulated GC×GC data, by first defining primary column 1D peak(s) and simulating the modulation process. Gaussian curve fitting is used to model each modulated secondary column separation peaklet, 2D, in the unfolded GC×GC data to accurately determine the maxima of the peaklet distribution, followed by Gaussian curve fitting to the maxima to determine the effective 1D peak profile and width, 1Wb*. The relationship between 1Wb and 1Wb* is studied as a function of the effective modulation ratio, MR*, which is 1Wb* divided by PM, in order to determine the true modulation ratio, MR, which is 1Wb divided by PM. We explore how peak sampling phase (in-phase and out-of-phase) plays a role in the relationship between MR and MR*. Experimental validation of the simulated results is also provided, to span a range of commonly implemented conditions with typical 1Wb (2-4.5s) and PM (0.25-8s). Use of MR<2 significantly broadens the 1D peak (MR*≥1.2MR) corresponding to a loss in 1D peak capacity, 1nc≥20%. The new method relies upon mapping from MR* to MR, which is discussed in relation to peak capacity theories for GC×GC. It is found that optimizing 1nc in GC×GC requires that 1Wb is minimized and must be sampled with a sufficiently short PM (1-2s) to minimize modulator induced band broadening and a subsequent reduction in the effective 1D peak capacity.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:22Nitrogen Compound Characterization in Fuels by Multidimensional Gas Chromatography
Published on: May 15, 2020
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...