Related Experiment Video
Updated: Mar 11, 2026

Lab-Scale Model to Evaluate Odor and Gas Concentrations Emitted by Deep Bedded Pack Manure
Published on: July 19, 2018
Evaluation of a sprinkler cooling system on inhalable dust and ammonia concentrations in broiler chicken production
S Williams Ischer1, M B Farnell2, G T Tabler2
1a Department of Occupational Environmental Health , University of Iowa , Iowa City , Iowa.
Abstract:
Workers are exposed to dust in broiler chicken production during daily work activities. Poultry dust may contain inflammatory agents (e.g., endotoxin) and inhalation exposure has been associated with pulmonary symptoms. Current practice to reduce worker exposure to poultry dust is the use of respiratory protection (e.g., elastomeric face-piece respirator with a P100 and ammonia chemical cartridge). Limited research has been conducted to evaluate engineering controls to reduce dust and ammonia concentrations in broiler chicken production; therefore, the purpose of this research was to evaluate the effectiveness of a water sprinkling system to reduce inhalable dust and ammonia concentrations in a broiler chicken house. Inhalable dust and ammonia concentrations were measured daily for the production cycle of a flock of broiler chickens (63 days). Inhalable dust was measured gravimetrically using an inhalable sampler and ammonia was measured by a direct reading sensor. Sampling was performed on a stationary mannequin inside two broiler chicken houses. One house used a sprinkler cooling system to deliver a water mist throughout the house and the second house was an untreated control. The sprinkler system activated after day 5 of chicken placement, releasing water periodically from 6 am to 10 pm. The amount of sprinkling increased at day 10 and day 15 as recommended by the manufacturer. Geometric mean (GM) inhalable dust concentrations measured in the treatment house (5.5 mg/m3) were not different (p = 0.33) than those found in the control house (6.0 mg/m3). The GM ammonia concentrations were also not different (p = 0.34) across the treatment and control house [10.6 ppm (GSD: 1.80); GM 9.51 ppm (GSD: 1.77)], respectively. The use of cost effective engineering, administrative and personal exposure controls are needed in the poultry industry to effectively reduce worker's exposure to hazardous concentrations of dust and ammonia.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
05:45Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
Published on: January 7, 2019