Body surface mapping using an ECG belt to characterize electrical heterogeneity for different left ventricular pacing
W Ben Johnson1, Pierce J Vatterott2, Michael A Peterson2
1Iowa Heart Center PC, Des Moines, Iowa.
Background:
Electrical heterogeneity (EH) during cardiac resynchronization therapy may vary with different left ventricular (LV) pacing sites.
Objective:
The purpose of this study was to evaluate the relationship between such changes and acute hemodynamic response (AHR).
Methods:
Two EH metrics-standard deviation of activation times and mean left thorax activation times-were computed from isochronal maps based on 53-electrode body surface mapping during baseline AAI pacing and biventricular (BiV) pacing from different pacing sites in coronary veins in 40 cardiac resynchronization therapy-indicated patients. AHR at different sites was evaluated by invasive measurement of LV-dp/dtmax at baseline and BiV pacing, along with right ventricular (RV)-LV sensing delays and QRS duration.
Results:
The site with the greatest combined reduction in standard deviation of activation times and left thorax activation times from baseline to BiV pacing was hemodynamically optimal (defined by AHR equal to, or within 5% of, the largest dp/dt response) in 35 of 40 patients (88%). Sites with the longest RV-LV and narrowest paced QRS were hemodynamically optimal in 26 of 40 patients (65%) and 28 of 40 patients (70%), respectively. EH metrics from isochronal maps had much better accuracy (sensitivity 90%, specificity 80%) for identifying hemodynamically responsive sites (∆LV dp/dtmax ≥10%) compared with RV-LV delay (69%, 85%) or paced QRS reduction (52%, 76%). Multivariate prediction model based on EH metrics showed significant correlation (R2 = 0.53, P <.001) between predicted and measured AHR.
Conclusion:
Changes in EH from baseline to BiV pacing more accurately identified hemodynamically optimal sites than RV-LV delays or paced QRS shortening. Optimization of LV lead location by minimizing EH during BiV pacing, based on body surface mapping, may improve CRT response.
More Related Videos
Related Concept Videos
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring