Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

X-ray Imaging01:24

X-ray Imaging

10.9K
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with...
10.9K
Imaging Biological Samples with Optical Microscopy01:18

Imaging Biological Samples with Optical Microscopy

12.0K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
12.0K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

14.7K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
14.7K
Spherical Coordinates01:23

Spherical Coordinates

16.7K
Spherical coordinate systems are preferred over Cartesian, polar, or cylindrical coordinates for systems with spherical symmetry. For example, to describe the surface of a sphere, Cartesian coordinates require all three coordinates. On the other hand, the spherical coordinate system requires only one parameter: the sphere's radius. As a result, the complicated mathematical calculations become simple. Spherical coordinates are used in science and engineering applications like electric and...
16.7K
High-Resolution Mass Spectrometry (HRMS)01:15

High-Resolution Mass Spectrometry (HRMS)

2.8K
The resolution of a mass spectrometer depends on the efficiency of separating ions with different ion masses. The mass of an atom is approximated to the sum of the masses of protons and neutrons inside, considering the masses of protons and neutrons as equal. However, the masses of the proton (1.6726 × 10−24 g) and neutron (1.6749 × 10−24 g) are not truly equal. There is a minor error in the expression of atomic masses relative to the simplest atom of hydrogen. For...
2.8K
IR Spectrometers01:25

IR Spectrometers

3.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

SAR-Efficient Sub-Volume Imaging Using Nonlinear Gradient Magnetic Fields.

Journal of imaging·2026
Same author

Patients' pain experience in claudication: Biopsychosocial correlates of frequency, intensity, sleep interference, and chronic pain.

The journal of pain·2026
Same author

Prospective serial cardiovascular magnetic resonance imaging of immune checkpoint inhibitor myocarditis correlates with cardiovascular outcomes.

Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance·2026
Same author

Using U-Nets to Predict the Effects of Head Motion on Simulated Specific Absorption Rate for Ultra-High Field Magnetic Resonance Imaging With Parallel Transmission.

Magnetic resonance in medicine·2026
Same author

AUTOMATED MEASUREMENTS OF MITRAL AND TRICUSPID ANNULAR DIMENSIONS IN CARDIOVASCULAR MAGNETIC RESONANCE.

Proceedings. IEEE International Symposium on Biomedical Imaging·2026
Same author

TVnet: Automated Time-Resolved Tracking of the Tricuspid Valve Plane in MRI Long-Axis Cine Images with a Dual-Stage Deep Learning Pipeline.

Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention·2026

Related Experiment Video

Updated: Mar 11, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

20.2K

O-space with high resolution readouts outperforms radial imaging.

Haifeng Wang1, Leo Tam1, Emre Kopanoglu1

  • 1Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT 06520, USA.

Magnetic Resonance Imaging
|November 24, 2016
PubMed
Summary
This summary is machine-generated.

O-Space imaging with extended readouts offers superior high-resolution, artifact-minimized images compared to radial imaging. This advanced technique preserves subtle details crucial for diagnostic applications.

Keywords:
High-resolutionNonlinear spatial encodingO-space imagingParallel imaging

More Related Videos

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K
Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

547

Related Experiment Videos

Last Updated: Mar 11, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

20.2K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.9K
Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment
07:12

Whole-cell Super-Resolution Imaging via DNA-PAINT on a Spinning Disk Confocal with Optical Photon Reassignment

Published on: January 6, 2026

547

Area of Science:

  • Magnetic Resonance Imaging (MRI)
  • Image Acquisition Techniques

Background:

  • O-Space imaging accelerates MRI acquisition beyond Cartesian methods.
  • Undersampled radial imaging is similar to O-Space but less studied for high-resolution applications.
  • Previous research focused on ultrafast imaging with high acceleration and low resolution.

Purpose of the Study:

  • Directly compare O-Space and radial imaging for high-resolution, undersampled diagnostic images.
  • Evaluate O-Space imaging's advantages with extended data acquisition readouts.
  • Assess image quality and artifact levels in high-resolution O-Space versus radial imaging.

Main Methods:

  • Developed a high-resolution readout sampling strategy for comparison.
  • Utilized simulations and phantom studies to compare O-Space and radial sequences.
  • Investigated extended readout windows in O-Space for improved k-space sampling and image quality.

Main Results:

  • O-Space imaging with high-resolution readouts produced sharper images with fewer artifacts than radial imaging.
  • Radial imaging with longer readouts exhibited increased undersampling artifacts, obscuring subtle image features.
  • O-Space imaging successfully preserved fine details that were lost in comparable radial images.

Conclusions:

  • High-resolution O-Space imaging achieves highly undersampled, high-resolution images with minimal artifacts.
  • The use of nonlinear gradient fields in O-Space enhances image quality over conventional radial imaging.
  • O-Space imaging demonstrates significant potential for diagnostic MRI applications requiring high resolution and minimal artifacts.