Related Experiment Video
Updated: Mar 11, 2026

A Novel Non-invasive Method for the Detection of Elevated Intra-compartmental Pressures of the Leg
Published on: May 31, 2019
Can non-invasive ventilation modify central venous pressure? Comparison between invasive measurement and
Maurizio Zanobetti1, Alessio Prota2, Alessandro Coppa2
1Emergency Department, Careggi University Hospital, Largo Brambilla, 3, 50134, Florence, Italy. zanomau@libero.it.
Abstract:
Central venous pressure (CVP) is primarily measured to assess intravascular volume status and heart preload. In clinical practice, the measuring device most commonly used in emergency departments and intensive care units, is an electronic transducer that interconnects a central venous catheter (CVC) with a monitoring system. Non-invasive ventilation (NIV) consists in a breathing support that supplies a positive pressure in airways through a mask or a cask though not using an endotracheal prosthesis. In emergency settings, non-invasive ultrasonography evaluation of CVP, and hence of intravascular volume status entail the measurement by a subxiphoid approach of inferior vena cava diameter and its variations in relation to respiratory activity. In the literature, there are many studies analyzing the ability to estimate CVP through ultrasonography, rating inspiratory and expiratory vena cava diameters and their ratio, defined as inferior vena cava collapsibility index (IVC-CI). At the same time, the effects of invasive mechanical ventilation on blood volume and the correlation during ventilation between hemodynamic invasive measurement of CVP and inferior vena cava diameters have already been demonstrated. Nevertheless, there are no available data regarding the hemodynamic effects of NIV and the potential correlations during this kind of ventilation between invasive and non-invasive CVP measurements. Therefore, this study aims to understand whether there exists or not an interrelationship between the values of CVP assessed invasively through a CVC and non-invasively through the IVC-CI in patients with severe respiratory distress, and above all to evaluate if these means of assessment can be influenced using NIV.
More Related Videos
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Mechanical Ventilation I: Indication and Settings
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:

