Related Experiment Video
Updated: Mar 11, 2026

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Patient-specific depth of endotracheal intubation-from anthropometry to the Touch and Read Method
Saecheol Oh1, Seunguk Bang2, Woojin Kwon3
1Dr., Saecheol Oh, MD, PhD. Department of Anaesthesiology and Pain Medicine College of Medicine, The Catholic University of Korea Seoul, Korea.
Objective:
Knowledge of accurate airway length (AL) enables safer placement of the endotracheal tube (ETT) in the trachea. Our objective was to check the safety of a new formula (Touch and Read method) to determine ETT depth.
Methods:
AL was measured in 176 patients. Patients were divided into a normal group (AL >25 cm in men, >23 cm in women) and a risk group (AL ≤25 cm in men, ≤23cm in women). A control test (Conventional method) was performed in which the ETT was secured at a depth of 23 cm from the central incisor in men and 21 cm in women. In the experimental test (Touch and Read method), the ETT was secured at a depth equal to the distance from the angle of the mouth to the epiglottis tip plus 12.5 cm in men and 11.5 cm in women. The mean distance from the tube tip to the carina and that from the vocal cords to tube cuff were compared between the control and experimental tests in each group.
Results:
The two distances were similar between control and experimental tests in the normal group, but differed in the risk group (Women: mean distance from tube tip to carina, 1.2 cm and from vocal cords to cuff, 2.7 cm [control test]; 1.9 and 2.0 cm, respectively [experimental test]. Men: 0.7 and 3.5 cm, respectively [control test]; 2.0 and 2.3 cm, respectively [experimental test]).
Conclusion:
Touch and Read method enables safer placement of the ETT in the trachea than the conventional method in the risk group.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes: