Most workers in auto part factories in Thailand are usually exposed to excessive noise in their workplace. This study aimed to assess the level of occupational noise-induced hearing loss and investigate risk factors causing hearing loss in auto part factory workers in the welding units in Thailand.
Methods:
This was a cross-sectional study. One hundred eighty subjects were recruited from 356 workers in the welding unit of three factories. Sixty eligible subjects in each factory were selected by systemic random sampling. The subjects were interviewed using a face-to-face questionnaire. Noise exposure levels and audiograms were measured by a noise dosimeter and an audiometer, respectively.
Results:
The findings confirmed that noise exposure levels of 86-90 dB (A) and exceeding 90 dB (A) significantly increased the risk of hearing loss in either ear. A noise exposure level exceeding 90 dB (A) significantly increased the prevalence of hearing loss in both ears. Regarding, a 10-pack-year smoking history increased the prevalence of hearing loss in either ear or both ears. In addition, subjects with employment duration exceeding 10 years significantly developed hearing loss in either ear.
Conclusions:
The engineering control or personal control by wearing hearing protection device should be used to decrease noise exposure levels lower than 85 dB (A) for 8 h. Moreover, if the exposure level reaches 85 dB (A) for 8 h, the employer needs to implement a hearing conservation program in the workplace.
More Related Videos
05:44Author Spotlight: Development of a Laser-Induced Shock Wave Animal Model Without Tympanic Membrane Perforation
Published on: March 1, 2024
06:27Simple Surgical Induction of Conductive Hearing Loss with Verification Using Otoscope Visualization and Behavioral Clap Startle Response in Rat
Published on: October 26, 2019
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
The Availability Heuristic
Hearing
Perception of Sound Waves
The pitch of a sound depends on the frequency and the pressure amplitude of the source. Two sounds of the same...