Optimization of sparse phase encodings for variable repetition-delay turbo-spin echo (TSE) T1 measurements for
DongKyu Lee1, Sohyun Han1, HyungJoon Cho1
1Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, Republic of Korea.
Abstract:
A variable repetition-delay (TR) spin echo sequence with repeated refocusing pulses, i.e., a variable TR turbo-spin echo (TSE), provides an attractive means of acquiring an accurate T1 map information that is free from gradient echo based artifacts such as magnetic field inhomogeneities particularly for ultra-high field (at 7T and above) preclinical applications. However, the applicability of multi-slice TSE sequences is often limited by signal distortion from T2 relaxation due to echo-train acquisitions for short T2 tissues, inter-slice cross talks and magnetization transfer (MT) from repetitive slice-selective 180° pulse, and extended scan times with multiple TR excitations. These TSE shortcomings are difficult to remedy for preclinical applications, where small sizes of target organs usually limit the slice-gap control with restricted parallel imaging capabilities. In this study, compressed-sensing-assisted turbo-spin echo (CS-TSE) acquisitions for variable TR T1 measurements at 7T preclinical scanner were implemented to reduce the echo-trains by sparse phase encodings. Following the sparse signal simulation and sampling scheme optimization, the measured T1 values from CS-TSE and TSE were compared for phantoms, ex vivo, and in vivo subjects. The phantom T1 values from CS-TSE and TSE were identical to those from the inversion recovery spin echo. For both ex vivo and in vivo multi-slice T1 mapping, the shortened echo-trains of CS-TSE relieved the T2 relaxation, reduced the inter-slice interferences of multi-slice acquisition, and made room for additional slice encodings while maintaining a shorter scan time than the conventional TSE at the expense of local image smoothness from CS regularizations.
More Related Videos
05:07Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
Published on: September 6, 2024
07:24Paramagnetic Relaxation Enhancement for Detecting and Characterizing Self-Associations of Intrinsically Disordered Proteins
Published on: September 23, 2021
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
NMR Spectrometers: Resolution and Error Correction
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)