Related Experiment Video
Updated: Mar 11, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
The impact of body mass index on dosimetric quality in low-dose-rate prostate brachytherapy
Michelle I Echevarria1, Arash O Naghavi1, Puja S Venkat1
1Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL, USA.
Purpose:
Low-dose-rate (LDR) brachytherapy has been established as an effective and safe treatment option for men with low and intermediate risk prostate cancer. In this retrospective analysis, we sought to study the effect of body mass index (BMI) on post-implant dosimetric quality.
Material And Methods:
After institutional approval, records of patients with non-metastatic prostate cancer treated in Puerto Rico with LDR brachytherapy during 2008-2013 were reviewed. All patients were implanted with 125I seeds to a prescription dose of 145 Gy. Computed tomography (CT) based dosimetry was performed 1 month after implant. Patients with at least 1 year of prostate-specific antigen (PSA) follow-up were included. Factors predictive of adequate D90 coverage (≥ 140 Gy) were compared via the Pearson χ2 or Wilcoxon rank-sum test as appropriate.
Results:
One-hundred and four patients were included in this study, with 53 (51%) patients having a D90 ≥ 140 Gy. The only factor associated with a dosimetric coverage detriment (D90 < 140 Gy) was BMI ≥ 25 kg/m2 (p = 0.03). Prostate volume (p = 0.26), initial PSA (p = 0.236), age (p = 0.49), hormone use (p = 0.93), percent of cores positive (p = 0.95), risk group (p = 0.24), tumor stage (p = 0.66), and Gleason score (p = 0.61) did not predict D90.
Conclusions:
In this study we show that BMI is a significant pre-implant predictor of D90 (< 140 Gy vs. ≥ 140 Gy). Although other studies have reported that prostate volume also affects D90, our study did not find this correlation to be statistically significant, likely because all of our patients had a prostate volume < 50 cc. Our study suggests that in patients with higher BMI values, more rigorous peri-implant dosimetric parameters may need to be applied in order to achieve a target D90 > 140 Gy.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Drug Dosing: Obese Patients
Dose-Response Relationship: Overview
Dose Size and Dosing Frequency: Determination Methods
Dose-Response Relationship: Potency and Efficacy