The interplay of network structure and dispatch solutions in power grid cascading failures
Jose M Reynolds-Barredo1, David E Newman2, Benjamin A Carreras1
1Departamento de Física, Universidad Carlos III de Madrid, 28911 Leganes, Madrid, Spain.
Chaos (Woodbury, N.Y.)
|December 3, 2016
Summary
Multiple electricity dispatch solutions can impact grid vulnerability to blackouts. Network structure, particularly clustering, influences this sensitivity, prompting research into mitigating discrepancies.
Area of Science:
- Power Systems Engineering
- Network Science
- Computational Social Science
Background:
- Electricity dispatch aims for minimum cost, but multiple equivalent solutions often exist.
- The choice of dispatch solution can influence the operational state and vulnerability of power grids.
Purpose of the Study:
- To investigate the sensitivity of power grid vulnerability to cascading failures based on different dispatch solutions.
- To identify network characteristics that affect this sensitivity.
- To explore methods for reducing discrepancies between dispatch solutions.
Main Methods:
- Network analysis to quantify structural properties like the clustering coefficient.
- Simulation of cascading failures under various dispatch scenarios.
- Sensitivity analysis of blackout statistics to dispatch choices.
Main Results:
- Blackout statistics are sensitive to the chosen dispatch solution, especially in heterogeneous networks.
- The clustering coefficient of the network is a key factor determining this sensitivity.
- Discrepancies between dispatch solutions can be reduced through specific mechanisms.
Conclusions:
- The selection of an electricity dispatch solution is critical and can significantly alter a network's vulnerability to cascading blackouts.
- Understanding network topology, specifically clustering, is essential for assessing blackout risk.
- Further research into dispatch optimization can enhance grid resilience.
Related Concept Videos
Primary Distribution
606
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
606
Reclosers and Fuses
513
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
513
Power System Distribution
1.2K
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
1.2K
Fast Decoupled and DC Powerflow
796
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
796
Zones of Protection
887
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
887
Secondary Distribution
615
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
615