Demonstration of low energy proton radiography on an 11-MeV cyclotron
Xiao Ding Zhang1, Guo Jun Yang1, Yi Ding Li1
1Institute of Fluid Physics, China Academy of Engineering Physics, P.O. Box 919-106, Mianyang 621900, China.
Abstract:
Lens focused proton radiograph on thin objects is demonstrated using an 11-MeV proton cyclotron at China Academy of Engineering Physics. The proton beam exiting from the tested objects is focused onto the image plane by a magnetic lens system mitigating image blur caused by multiple Coulomb scattering. Both simulations and experiments show that clear images can be obtained with a lens system for the objects with thickness up to 2.7 × 10-2 g/cm2 and the error for the areal density measurement is measured to be less than 2.3%. For the objects with thickness between 2.7 × 10-3 g/cm2 and 2.7 × 10-2 g/cm2, 100-200 μm of spatial resolution is achieved.