High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
Beam emission spectroscopy with radially and poloidally elongated optical sightlines
M Ono1, K Ida2, T Kobayashi2
1Department of Fusion Science, SOKENDAI (The Graduate University for Advanced Studies), Toki, Gifu 509-5292, Japan.
Abstract:
Beam emission spectroscopy is widely used as local density fluctuation measurement of fusion plasmas. We have installed a beam emission spectroscopy system in the large helical device (LHD) with radially and poloidally elongated optical configuration to enhance both signal-to-noise ratio and wavenumber sensitivity in radial and poloidal directions. The calculation considering the integral effect of the line of sight showed the radially and poloidally elongated sightlines have increased sensitivity compared with the square shaped bundle design of the same sampling area.