Related Experiment Video
Updated: Mar 11, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Pulmonary artery dissection following balloon valvuloplasty in a dog with pulmonic stenosis
1Department of Medical Sciences, School of Veterinary Medicine, University of Wisconsin, 2015 Linden Dr. Madison, WI 53706, USA.
Abstract:
A 3-month-old, 9.9 kg, male pit bull cross was referred for evaluation of collapse. A left basilar systolic heart murmur graded V/VI and a grade IV/VI right basilar systolic heart murmur were ausculted. Echocardiography showed severe pulmonic stenosis characterized by annular hypoplasia, leaflet thickening, and leaflet fusion. After 1 month of atenolol therapy, a pulmonic valve balloon valvuloplasty procedure was performed, and the intra-operative right ventricular pressure was reduced by 43%. Echocardiography, performed the following day, showed apparent rupture of a pulmonary valve leaflet and a membranous structure within the pulmonary artery consistent with a dissecting membrane. Short-term follow-up has shown no apparent progression of the pulmonary artery dissection and the patient remains free of clinical signs.