Published on: June 4, 2020
Intra- and inter-tester reliability and validity of normal finger size measurement using the Japanese ring gauge
T Suzuki1,2, Y Sato3, S Sotome3
11 Department of Orthopaedic Surgery, Fujita Health University, Toyoake, Japan.
Abstract:
This study was designed to investigate the reliability and validity of measurements of finger diameters with a ring gauge. A reliability study enrolled two independent samples (50 participants and seven examiners in Study I; 26 participants and 26 examiners in Study II). The sizes of each participant's little fingers were measured twice with a ring gauge by each examiner. To investigate the validity of the measurements, five hand therapists compared the finger size and hand volume of 30 participants with the ring gauge and with a figure-of-eight technique (Study III). The intra-class correlation coefficient for intra-observer reliability ranged from 0.97 to 0.99 in Study I, and 0.90 to 0.97 in Study II. The intra-class correlation coefficient for inter-observer reliability was 0.95 in Study I and 0.94 in Study II. The validity study showed a Pearson product moment correlation coefficient of 0.75. The ring gauge showed high reliability and validity for measurement of finger size.
Level Of Evidence:
III, diagnostic.
Related Concept Videos
Uncertainty in Measurement: Reading Instruments
Reliability and Validity
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Assessment of blood pressure in brachial artery(two-step method)
Measurements of Strain