Abstract:
Two-dimensional (2D) gel electrophoresis is a well-proven proteomic technique; however, sample-specific optimisation can often be necessary in order to get consistent quantitation. In particular, plasma samples are often smeared on 2D gels making spot matching difficult. A variety of different sample preparation and 2D methods were tested by using sheep plasma, and it was found that lowering sample pH prior to precipitation, using a long voltage gradient for isoelectric focusing and the inclusion of carrier ampholytes in the electrode wicks, improved both the quality and consistency of spot resolution. Analysis of the internal standards from two different DIGE experiments, one with conventional methodology and one with the improved method, showed that along with substantially improving the number of spots resolved, the average CV (coefficient of variation) of matched standards was lower with the new method. 428 matched spots were found using the improved method compared to 208 matched spots using conventional methodology. For the 174 spots that were matched between the two DIGE experiments, the average CV's of spot volumes were also significantly lower, at 0.20 for the new method compared to 0.24 for the conventional method (p < 0.001).
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact...
DNA Agarose Gel Electrophoresis
Gel extraction follows five major steps: running gel electrophoresis to separate fragments, isolating the individual bands, extracting DNA from those bands, and removing the dye and salts from the extracted mixture to obtain pure DNA.
In cloning experiments, both the insert and vector DNA...
Electrophoresis: Overview
There...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.