Related Experiment Video
Updated: Mar 10, 2026

Clinical Efficacy of Ultrasound-Assisted Scoliosis-Specific Exercise in Mild-Grade Adolescent Idiopathic Scoliosis
Published on: December 2, 2025
Computed Tomography Lung Volume Changes After Surgical Treatment for Early-Onset Scoliosis
Charles E Johnston1, Anna McClung1, Salah Fallatah2
1Texas Scottish Rite Hospital for Children, 2222 Welborn Street, Dallas, TX 75209, USA.
Study Design:
Single-center review of prospectively collected data.
Objectives:
To document anatomic lung volume and thoracic parameter changes in early-onset scoliosis patients undergoing rib-based (RB), or spine-based (SB) distraction surgical treatment who were too young to perform pulmonary function tests.
Methods:
Twenty patients undergoing growth-sparing treatment had computed tomography lung volumes (CTvol) determined by controlled-ventilation CT scanning preoperatively and at a mean of 2.7 years later under an institutional review board (IRB)-approved protocol. Twelve patients had non-congenital curves and 8 had congenital curves. Eleven patients had SB constructs and 9 had RB ones. Computed tomography lung volumes were correlated to T1-12 length, T6 coronal width, pelvic width, and curve magnitude, and were normalized by comparison with age standards and pelvic width.
Results:
All patients had increased CTvol at follow-up (RB 51%, SB 46%; p < .001). All increased T1-12 length from 128 mm (range, 39-160 mm) preoperatively to 154 mm (range, 61-216 mm) at follow-up. Both RB and SB gained 2.6 cm; this measurement was significant in RB (p < .001) owing to the shorter preoperative length. The T1-12 length correlated well with CTvol preoperatively (p = .002) and at follow-up (p = .007). The T6 width correlated best with CTvol (r = 0.76; p < .001 preoperatively and at follow-up). Main thoracic curves improved 21° in SB (preoperatively, 78°) versus 1.5° correction in RB (preoperatively, 60.2°). There was no correlation between curve magnitude and CTvol preoperatively or at follow-up. Follow-up CTvol percentile decreased in 10 patients, increased in 6, and was unchanged in 4. The T1-12 length was less than the fifth percentile in all patients preoperatively and increased in 9 patients at follow-up, whereas 11 remained at less than the fifth percentile.
Conclusions:
The CTvol quantitates anatomic results of early-onset scoliosis growth-sparing surgery in patients too young for standard pulmonary function tests. Thoracic length and width correlate well with absolute CTvol and are possible surrogate measures. Curve magnitude and correction correlate poorly and assume less importance in outcome evaluation. Thoracic volume and length gains exceeded normal growth in about half of the patients.
More Related Videos
03:38Unilateral Lung Volume Analysis Using Micro-CT for Enhanced Assessment of Pulmonary Fibrosis in Preclinical Models
Published on: June 20, 2025
08:39Longitudinal Micro-Computed Tomography Image Analysis for User-Defined Region of Interest in Critical-Sized Bone Defects
Published on: June 24, 2025
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Imaging Studies III: Computed Tomography