Related Experiment Video
Updated: Mar 10, 2026

Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
Published on: May 24, 2017
Validating Use of Internet-Submitted Carbon Monoxide Values by Video to Determine Quit Status
Joshua L Karelitz1, Valerie C Michael1, Margaret Boldry1
1Department of Psychiatry, University of Pittsburgh School of Medicine, Pittsburgh, PA.
Introduction:
Daily visits to biochemically verify continuous smoking abstinence via expired-air carbon monoxide (CO) may deter participation in cessation trials. One way to reduce need for daily visits while continuing to monitor abstinence success may be use of a recent procedure to verify abstinence from daily CO values via the Internet. This method requires participants submit to study staff video recordings of themselves correctly using a CO monitor. However, it has not been clearly demonstrated that those classified quit via Internet-submitted videos of CO would be reliably classified quit when assessed in lab.
Methods:
Our study examined agreement in quit status from Internet-submitted CO values with quit status via CO collected in later same-day lab visits. Participants (n = 23) were from a short-term cessation study who agreed to record and submit videos of offsite CO testing, in addition to attending daily lab visits. All CO values were obtained via Bedfont pico+ Smokerlyzer monitors, with CO < 8 ppm indicating quit. During two 4-day practice quit attempts, a video was submitted before daily lab visits, up to eight videos each.
Results:
Of the total of 150 videos submitted, 97 videos indicated "not quit" and 53 "quit." Cohen's Kappa indicated substantial agreement in quit status between assessments, 0.70, p < .001, as 85% of the videos indicating "quit" CO were also "quit" CO in lab.
Conclusions:
To our knowledge, these results are the first validation of daily Internet-submitted CO values to confirm daily quit status, supporting the utility of this approach for close monitoring of continuous abstinence.
Implications:
This study compared consistency between quit status from CO values submitted over the Internet and quit status via CO collected in later same-day lab visits. Findings indicate substantial agreement in quit status between these two methods of CO assessment. Our results validate the use of Internet-submitted CO values to verify daily quit status. This method can be used in future cessation trials as a means to biochemically validate continuous abstinence without the burden of daily lab visits or relying on self-report of recent smoking lapses.
More Related Videos
06:39Electroencephalographic, Heart Rate, and Galvanic Skin Response Assessment for an Advertising Perception Study: Application to Antismoking Public Service Announcements
Published on: August 28, 2017
07:52Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.