Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary
Xia Yang1, Qiang Yu2, Wei Dong1
1Department of Cardiology, Chinese PLA General Hospital, Beijing, China.
Objective:
To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral (HPS) mode for coronary stents patency.
Methods:
We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode.
Results:
There was no significant impact of age, body mass index or heat rate (HR) on image quality (P > 0.05), while HR variability had a slight impact on that (P < 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant difference on sensitivity, specificity, PPV and NPV between diameter ≥ 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter < 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P < 0.05), and that between stent number ≥ 3 group (82.3%, 77.8%, 66.7%, and 60%) with < 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P < 0.01)].
Conclusion:
DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR < 65 beats/min.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Mitral Stenosis II: Clinical features and Diagnostic Tests
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT