Related Experiment Video
Updated: Mar 10, 2026

Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
Silica-supported polymeric monolithic column with a mixed mode of hydrophilic and strong cation-exchange interactions
Hang Ren1, Xinyue Zhang1, Zhen Li1
1Department of Chemistry, Liaoning Normal University, Dalian, China.
Abstract:
A novel sulfonic acid group containing hydrophilic strong cation-exchange monolith was prepared by in situ coating 5 μm bare silica particles with the copolymers of glycidyl methacrylate and pentaerythritol triacrylate and further sulfonating the prepared polymer matrix with Na2 SO3 inside a 150 μm id capillary. The preparation conditions were investigated, and the method was described in detail. The prepared column was characterized by comparing with its counterparts reported previously in terms of matrix morphology, preparation reproducibility, permeability, swelling-shrinking behavior, mechanical stability, hydrophilicity, binding capacity, and column efficiency. The swelling-shrinking behavior of the present column in solvents of different polarities was negligible, the hydrophobicity could be suppressed at the acetonitrile concentrations higher than 40% v/v, and the binding capacities were 256 μequiv/mL and 20.1 mg/mL for Cu2+ and lysozyme, respectively. The minimum theoretical plate heights were 8, 10, and 13 μm, and the values of the C term in van Deemter equation were 9, 12, and 35 ms for the test analytes of Na+ , thiourea, and cytidine 5'-monophosphate, respectively. This column exhibited an excellent performance in the separations of monovalent inorganic cations, uncharged polar, and charged polar compounds.
More Related Videos
10:21Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Ion Exchange
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Elution Process