Published on: February 14, 2017
Arterial pulse wave propagation velocity in healthy dogs by pulse wave Doppler ultrasound
Rodrigo B Nogueira1, Lucas A Pereira2, Alice F Basso2
1Department of Veterinary Medicine, Federal University of Lavras, Postal Code 3037, 37200-000, Lavras, Minas Gerais, Brazil. nogueirarb@uol.com.br.
Abstract:
The aim of this study was to prospectively evaluate the carotid-femoral pulse wave velocity (PWV) values in healthy dogs using pulse wave Doppler ultrasound. A secondary aim was to determine the feasibility of this method and to report the intra- and interobserver reproducibilities of the PWV in conscious dogs. The data were studied in 30 healthy, adult, male (n = 15) and female (n = 15) dogs. The time interval marked between the R wave peak of the electrocardiogram and the intersection of the blood flow wave upstroke of the Doppler spectrum with the baseline of zero frequency was determined for the carotid (T1) and for the femoral (T2) arteries. The distance covered by the pulse wave (L) was determined. The PWV was then calculated using the following formula: L/T2 - T1. The mean values of PWV calculated from the total sample (n = 30) evaluated were 13.41 ± 2.20 m/s. No significant statistical difference was observed for the PWV measurements between males (14.82 ± 3.18 m/s) and females (12.64 ± 2.45 m/s). The analysis revealed no intra nor interobserver differences. A reasonable reproducibility of the PWV measurements was showed by intraclass correlation coefficients (ICC), and the coefficients of variation (CV). These data demonstrate that noninvasive vascular Doppler analysis is a feasible and reproducible method to determine the carotid-femoral PWV in dogs.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Special considerations while measuring pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...