Related Experiment Video
Updated: Mar 10, 2026

Author Spotlight: Translational Applications of Stimulated SFEMG in Rodent Models
Published on: March 8, 2024
Single-fiber EMG with concentric electrodes in lambert-eaton myasthenia
Yuzhou Guan1, Qingyun Ding1, Mingsheng Liu1
1Department of Neurology, Peking Union Medical College Hospital, No. 1 Shuaifuyuan, Wangfujing, Dongcheng, Beijing, China, 100730.
Introduction:
We analyzed jitter recordings made with concentric needle electrode (CNE) single-fiber electromyography (SFEMG) in Lambert-Eaton myasthenia (LEM).
Methods:
Fifteen subjects diagnosed with LEM were studied using CNE-SFEMG in the extensor digitorum (ED) and tibialis anterior (TA) muscles. CNE-SFEMG in the ED and TA was also used to evaluate 12 and 10 healthy controls (HCs), respectively.
Results:
Ten men and 5 women were diagnosed with LEM based on an increase of 100% in compound muscle action potential amplitude during 50 Hz repetitive nerve stimulation. All patients exhibited markedly greater jitter in the ED (88.8 ± 23.2 µs) and TA (92.2 ± 30.2 µs) than HCs (28.3 ± 3.4 µs and 30.9 ± 5.1 µs, respectively).
Conclusions:
CNE-SFEMG is sensitive for discovering abnormalities in neuromuscular transmission in LEM. Muscle Nerve 56: 253-257, 2017.