Related Experiment Video
Updated: Jul 28, 2026

Digital Microfluidics for Automated Proteomic Processing
Published on: November 6, 2009
Automated Strong Cation-Exchange Cleanup To Remove Macromolecular Crowding Agents for Protein Hydrogen Exchange Mass
Farai I Rusinga1, David D Weis1
1Department of Chemistry and the Ralph N. Adams Institute for Bioanalytical Chemistry, University of Kansas , Lawrence, Kansas 66045, United States.
Abstract:
Measuring amide hydrogen exchange (HX) of intrinsically disordered proteins (IDPs) in solutions containing high concentrations of macromolecular crowding agents would give new insights into the structure and dynamics of these proteins under crowded conditions. High concentrations of artificial crowders, required to simulate cellular crowding, introduce overwhelming interferences to mass spectrometry (MS) analysis. We have developed a fully automated, dual-stage online cleanup that uses strong cation-exchange (SCX) followed by reversed-phase desalting to remove Ficoll, a synthetic polymer, for HX-MS analysis of proteins under crowded conditions. We tested the efficiency of our method by measuring the HX-MS signal intensities of myoglobin peptides from crowded samples containing 300 g L-1 Ficoll and from uncrowded samples. Although there was loss of abundance relative to uncrowded myoglobin analyzed using conventional HX-MS, 97% coverage of the myoglobin sequence was still obtained. Control HX-MS experiments using unstructured peptides labeled at pD 4.0 under crowded and uncrowded conditions confirmed that Ficoll does not alter chemical exchange and that the same extent of HX is achieved in uncrowded solutions as in solutions containing 300 g L-1 of predeuterated Ficoll. We validated our method by measuring HX of CBP, the intrinsically disordered nuclear coactivator binding domain of CREB binding protein (UniProt CBP_MOUSE P45481 ), residues 2059-2117, at pD 6.5 under crowded and uncrowded conditions. Ficoll induced both protection and deprotection from HX in different regions of CBP, with the greatest deprotection occurring at the edges of helices. These results are consistent with previous observation of IDPs under the influence of synthetic polymers.
More Related Videos
05:45Capillary Electrophoresis-based Hydrogen/Deuterium Exchange for Conformational Characterization of Proteins with Top-down Mass Spectrometry
Published on: June 8, 2021
08:40Millisecond Hydrogen/Deuterium-Exchange Mass Spectrometry for the Study of Alpha-Synuclein Structural Dynamics Under Physiological Conditions
Published on: June 23, 2022
Related Concept Videos
Ion Exchange
Ion-Exchange Chromatography