Move Suppression Calculations for Well-Conditioned MPC
Related Experiment Video
Updated: Mar 10, 2026

A Modeling and Simulation Method for Preliminary Design of an Electro-Variable Displacement Pump
Published on: June 1, 2022
1School of Science & Engineering, Teesside University, Middlesbrough TS1 3BA, UK.
Abstract:
Several popular tuning strategies applicable to Model Predictive Control (MPC) schemes such as GPC and DMC have previously been developed. Many of these tuning strategies require an approximate model of the controlled process to be obtained, typically of the First Order Plus Dead Time type. One popular method uses such a model to analytically calculate an approximate value of the move suppression coefficient to achieve a desired condition number for the regularized system dynamic matrix; however it is not always accurate and tends to under-estimate the required value. In this paper an off-line method is presented to exactly calculate the move suppression coefficient required to achieve a desired condition number directly from the unregularized system dynamic matrix. This method involves an Eigendecomposition of the system dynamic matrix - which may be too unwieldy in some cases -and a simpler analytical expression is also derived. This analytical expression provides a guaranteed tight upper bound on the required move suppression coefficient yielding a tuning formula which is easy to apply, even in on-line situations. Both methods do not require the use of approximate or reduced order process models for their application. Simulation examples and perturbation studies illustrate the effectiveness of the methods in both off-line and on-line MPC configurations. It is shown that accurate conditioning and improved closed loop robustness can be achieved.
Related Concept Videos
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
PD Controller: Design
Designing a continuous-data controller requires selecting and linking components like adders and integrators, which are fundamental in Proportional,...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Mechanistic Models: Compartment Models in Algorithms for Numerical Problem Solving
In individual population analyses, different algorithms are employed, such as Cauchy's method, which uses a...
