Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Early experience with the Venus p‑valve for percutaneous pulmonary valve implantation in native outflow tract
1Departamento de Cardiología Pediátrica y Enfermedades Respiratorias, Hospital Clínico de la Universidad Católica de Chile, Pontificia Universidad Católica de Chile, Santiago Chile, Chile. fgaray@med.puc.cl.
Introduction:
The Venus p‑valve (MedTech, Shanghai, China) is a self-expanding percutaneous heart valve designed to be implanted in a native patched right ventricle outflow tract. The worldwide clinical experience with this valve is just beginning and the results have so far been encouraging. We present our initial early experience implanting the Venus p‑valve in the native right ventricle outflow tract of patients with Tetralogy of Fallot repaired with a transannular patch.
Methods:
In 10 selected patients a procedure for percutaneous pulmonary valve implantation was performed using the Venus p‑valve. The patients mean age was 32 years (13-57), mean weight 59.6 kg (40-80). All patients had Tetralogy of Fallot with moderate to severe pulmonary regurgitation and an indication for pulmonary valve replacement.
Results:
The implantation procedure was successful in all the patients resulting in an immediately functional valve. No procedure-related complications were observed. Follow-up after 12 months (4-21) resulted in an improvement in NYHA class. There was a reduction of the mean right ventricle diastolic volume from 139 ml/m2 (105-179) to 78 ml/m2 (65-100) and improvement in the regurgitation fraction from 42% (29-58) to 1% (0-5), as seen on routine cardiac magnetic resonance 6 months after the implantation. No stent fractures have been observed so far.
Conclusion:
Percutaneous pulmonary valve implantation with the Venus p‑valve resulted in a safe and effective procedure. The valve has predictable and sustained functional competence, resulting in clinical improvement in the patients.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...