Related Experiment Video
Updated: Aug 15, 2026

Measuring the 50% Haemolytic Complement (CH50) Activity of Serum
Published on: March 29, 2010
Use of serum ultrafiltrate in the serum dilution test
J E Leggett1, S A Wolz, W A Craig
1Medical Service, William S. Middleton Memorial Veterans Hospital, Madison, WI 53705.
Although pooled human serum diluent is advocated in the serum dilution test, its use may compensate for protein binding defects in patients and yield nonrepresentative titers. To test this hypothesis, comparison was made of serum ultrafiltrate (molecular weight cutoff less than or equal to 30,000) serially diluted into either pooled serum ultrafiltrate or Mueller-Hinton broth with patient serum samples diluted into pooled human serum in 111 assays from 55 patients and 6 volunteers. Of 111 bactericidal titers in ultrafiltrate and/or Mueller-Hinton broth, 101 were within a single twofold dilution of titers in pooled human serum. Nine of 10 discordant titers involved highly bound drugs and were usually higher in ultrafiltrate than in pooled human serum. In seven additional volunteers with renal failure, titers in ultrafiltrate and in each volunteer's serum were higher than those diluted in pooled human serum (P = .002). Recommended methods using pooled serum diluent may not accurately predict actual bactericidal titers in patients with abnormal protein binding.
Although pooled human serum diluent is advocated in the serum dilution test, its use may compensate for protein binding defects in patients and yield nonrepresentative titers. To test this hypothesis, comparison was made of serum ultrafiltrate (molecular weight cutoff less than or equal to 30,000) serially diluted into either pooled serum ultrafiltrate or Mueller-Hinton broth with patient serum samples diluted into pooled human serum in 111 assays from 55 patients and 6 volunteers. Of 111 bactericidal titers in ultrafiltrate and/or Mueller-Hinton broth, 101 were within a single twofold dilution of titers in pooled human serum. Nine of 10 discordant titers involved highly bound drugs and were usually higher in ultrafiltrate than in pooled human serum. In seven additional volunteers with renal failure, titers in ultrafiltrate and in each volunteer's serum were higher than those diluted in pooled human serum (P = .002). Recommended methods using pooled serum diluent may not accurately predict actual bactericidal titers in patients with abnormal protein binding.
More Related Videos
09:00High Throughput Sequential ELISA for Validation of Biomarkers of Acute Graft-Versus-Host Disease
Published on: October 31, 2012
09:22Protein Digestion, Ultrafiltration, and Size Exclusion Chromatography to Optimize the Isolation of Exosomes from Human Blood Plasma and Serum
Published on: April 13, 2018
Related Concept Videos
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Drug Dosing in Renal Diseases: Measurement of Serum Creatinine Concentration and Clearance
Serum Studies: Renal Function Tests