Delayed recognition of an oximeter malfunction.

F E Block1

  • 1Department of Anesthesiology, Indian River Memorial Hospital, Vero Beach, FL.

International Journal of Clinical Monitoring and Computing
|April 1, 1989
PubMed
Summary

Pulse oximeters can provide falsely low readings even with a strong signal, potentially delaying problem identification. Anesthesiologists should be aware of this limitation to ensure patient safety.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Observations on use of wrong agent in an anesthesia agent vaporizer.

Journal of clinical monitoring and computing·2003
Same author

Optimization of alarms: a study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance.

Journal of clinical monitoring and computing·2003
Same author

A proposed new set of alarm sounds which satisfy standards and rationale to encode source information.

Journal of clinical monitoring and computing·2003
Same author

The Diatek Arkive "Organizer" patient information management system: experience at a university hospital.

Journal of clinical monitoring and computing·1998
Same author

Technology evaluation report: obtaining pulse oximeter signals when the usual probe cannot be used.

International journal of clinical monitoring and computing·1997
Same author

Pre-operative oximetry and capnometry: potential respiratory screening tools.

International journal of clinical monitoring and computing·1996

Area of Science:

  • Anesthesiology
  • Biomedical Engineering
  • Medical Device Technology

Background:

  • Pulse oximetry is a standard monitoring tool in anesthesia.
  • Clinicians often trust oximeter readings if the signal appears stable.
  • Oximeter reliability is generally assumed in the absence of known interference.

Observation:

  • A case report details an incident where a pulse oximeter displayed falsely low oxygen saturation values.
  • The oximeter presented a strong signal and good pulse amplitude, mimicking normal function.
  • External light or dye interference was not identified as the cause.

Findings:

  • The oximeter's readings were inaccurate despite appearing to function correctly.
  • Reliance on the seemingly normal oximeter data led to a delay in diagnosing the actual patient issue.
  • This highlights a potential failure mode of pulse oximetry technology.

Implications:

  • Anesthesiologists must maintain clinical vigilance and not solely rely on oximeter displays.
  • Further research into oximeter limitations and failure modes is warranted.
  • Ensuring accurate patient monitoring requires awareness of potential device inaccuracies.