Related Experiment Video
Updated: Mar 10, 2026

A Precision Medicine Tool for Measurement and Monitoring of Hemoglobin S in Sickle Cell Disease Patients Receiving Transfusion Therapy
Transcranial Doppler in hemoglobin SC disease.
Camilo Vieira1,2, Carolina Nogueira Costa de Oliveira3, Ludmila Araújo Borges de Figueiredo3
1Ambulatório Pediátrico de Doença Cerebrovascular, Hospital Universitário Professor Edgard Santos, Universidade Federal da Bahia, Bahia, Brazil.
Transcranial Doppler (TCD) velocities are lower in children with hemoglobin SC disease (HbSC) compared to sickle cell anemia (SCA). This finding suggests a need for different stroke risk assessment guidelines for HbSC patients.
Area of Science:
- Neurology
- Hematology
- Pediatrics
Background:
- Stroke is a significant complication in sickle cell disease (SCD).
- Current stroke risk guidelines are primarily based on sickle cell anemia (SCA) and HbS/β-thalassemia genotypes.
- Limited data exist on transcranial Doppler (TCD) flow velocities in hemoglobin SC disease (HbSC).
Purpose of the Study:
- To compare cerebral blood flow, specifically TCD velocities, in pediatric patients with SCD stratified by genotype.
- To investigate potential differences in TCD velocity measurements between SCA and HbSC genotypes.
Main Methods:
- A cohort of 1,664 pediatric patients with SCD underwent TCD velocity screening.
- Time-averaged maximum mean velocity (TAMM) was measured in the middle cerebral artery (MCA) and internal carotid artery (ICA).
- Data were analyzed comparing TAMM values between SCA and HbSC genotypes.
Main Results:
- Abnormal velocities were not detected in the anterior cerebral artery (ACA).
- Mean TAMM in the ICA/MCA was significantly lower in HbSC patients (104.9 ± 19.3 cm/s) compared to SCA patients (134.5 ± 30.5 cm/s).
- TAMM showed a negative correlation with hemoglobin and hematocrit levels in both genotypes.
Conclusions:
- TCD velocities are significantly lower in pediatric HbSC patients compared to SCA patients.
- This suggests that current cut-off values for abnormal TCD velocities may not be appropriate for HbSC.
- Further research is needed to establish specific stroke risk assessment guidelines for HbSC genotype.
More Related Videos
10:41Analysis of Cerebral Vasospasm in a Murine Model of Subarachnoid Hemorrhage with High Frequency Transcranial Duplex Ultrasound
Published on: June 3, 2021
08:23Characterization of Sickling During Controlled Automated Deoxygenation with Oxygen Gradient Ektacytometry
Published on: November 5, 2019
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...