Trabecular Meshwork Response to Pressure Elevation in the Living Human Eye
Published on: June 20, 2015
[Tono-pen versus manometer. Comparative measurements of intraocular pressure in human cadaver eyes]
V Hessemer1, R Rössler, K W Jacobi
1Univ.-Augenklinik Giessen.
Abstract:
A new hand-held tonometer, the Tono-Pen (TP), was compared with a Statham membrane manometer (MAN). The TP is a pen-sized Mackay-Marg tonometer with electronic signal analysis and digital pressure display. Comparative measurements of intra-ocular pressure (IOP) were performed on six cadavers (12 eyes in situ), 3-6 hours after death. The IOP was changed in 5 to 10 mm Hg steps in a range between 0 and 60 mm Hg by an infusion system. As compared to the manometrically determined IOP, the TP gave small overestimation of IOP below 17 mm Hg and a small underestimation above 17 mm Hg (maximum deviation 2.5 mm Hg). The mean values of 29.9 (TP) and 30.4 mm Hg (MAN) were not significantly different (p greater than 0.05, analysis of variance). The correlation coefficient was 0.99. The relationship between TP (y axis) and MAN (x axis) pressure readings is characterized exactly by a slightly curvilinear graph (y = 0.82x + 0.0002x2 + 2.52; mm Hg). This may be approximated by a regression line with a slope of 0.94, a y intercept of 1.46 mm Hg and a standard deviation of the TP readings in relation to the regression line of 2.36 mm Hg. In conclusion, the good agreement between TP and MAN pressure readings is superior to the recently described agreement between TP and Goldmann tonometer readings.
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...