Contrast-Enhanced Tissue Harmonic Imaging versus Phase Inversion Harmonic Sonographic Imaging for the Delineation of
Masashi Kono1, Yasunori Minami, Mina Iwanishi
1Department of Gastroenterology and Hepatology, Kindai University Faculty of Medicine, Osaka-Sayama, Japan.
Objective:
To compare contrast tissue harmonic imaging (THI) with low mechanical index (MI) and conventional contrast harmonic imaging (CHI) with respect to lesion visibility of hepatocellular carcinoma (HCC).
Methods:
One hundred and twenty-five patients (84 men and 41 women, age range 39-94 years, mean age 74 years) with 100 naïve HCCs and 30 lesions after radiofrequency ablation (RFA) for HCC were evaluated. One hundred and four patients had liver cirrhosis of Child-Pugh class A, and the remaining 21 had Child-Pugh class B cirrhosis. The lesion conspicuity and intratumoral echogenicity during the postvascular phase were compared using conventional CHI and contrast THI with low MI.
Results:
The MI values ranged from 0.20 to 0.30 on conventional CHI and from 0.30 to 0.35 on contrast THI. Regarding HCC lesion conspicuity, contrast THI with low MI was clearer in 79 lesions (60.8%), equal in 34 lesions (26.2%), and less clear in 17 lesions (13.1%) when compared with conventional CHI. The lesion conspicuity with contrast THI was significantly better than that with conventional CHI (p < 0.01). All of the postablative lesions were well delineated in patients who received RFA.
Conclusion:
Low-MI contrast THI was superior to conventional CHI with respect to lesion visibility of HCCs and might offer good imaging for the guiding of RFA.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound HIFU Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound HMIFU
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Ultrasonography
During an ultrasonography procedure, a handheld device called...