Measuring Sensitivity to Viewpoint Change with and without Stereoscopic Cues
Published on: December 4, 2013
Measurement of crosstalk in stereoscopic display systems used for vision research
Daniel H Baker1, Milena Kaestner2, André D Gouws3
1Department of Psychology, University of York, York, UKdaniel.baker@york.ac.ukhttp://www.york.ac.uk/psychology/staff/academicstaff/daniel/.
Abstract:
Studying binocular vision requires precise control over the stimuli presented to the left and right eyes. A popular technique is to segregate signals either temporally (frame interleaving), spectrally (using colored filters), or through light polarization. None of these segregation methods achieves perfect isolation, and so a degree of crosstalk is usually apparent, in which signals intended for one eye are faintly visible to the other eye. Previous studies have reported crosstalk values mostly for consumer-grade systems. Here we measure crosstalk for eight systems, many of which are intended for use in vision research. We provide benchmark crosstalk values, report a negative crosstalk effect in some LCD-based systems, and give guidelines for dealing with crosstalk in different experimental paradigms.