Evaluation of the WinROP system for identifying retinopathy of prematurity in Czech preterm infants

Juraj Timkovic1,2,3, Martina Pokryvkova4, Katerina Janurova5

  • 1Clinic of Ophthalmology, University Hospital Ostrava, Czech Republic.

Insights

The WinROP system accurately identifies high-risk Retinopathy of Prematurity (ROP) in Czech infants, showing 100% sensitivity. However, it generates many false positives, limiting its use for less severe ROP cases.

Area of Science:

  • Neonatology
  • Ophthalmology
  • Medical Informatics

Background:

  • Retinopathy of Prematurity (ROP) is a critical condition in preterm infants requiring accurate risk assessment.
  • The WinROP system predicts ROP risk using birth weight and weight changes, but its population-specific performance is unknown.
  • Evaluating WinROP in the Czech population is essential for its clinical application.

Purpose of the Study:

  • To assess the test characteristics of the WinROP system in Czech preterm infants.
  • To determine the sensitivity, specificity, positive predictive value, and negative predictive value of WinROP for ROP prediction.
  • To evaluate WinROP's utility in identifying infants at risk for severe ROP.

Main Methods:

  • Retrospective analysis of data from 445 preterm infants undergoing ROP screening.
  • Comparison of WinROP predictions with regular screening outcomes at University Hospital Ostrava.
  • Evaluation of WinROP's performance metrics for high-risk and low-risk ROP.

Main Results:

  • WinROP achieved 100% sensitivity and negative predictive value for high-risk ROP (Type 1 or Type 2).
  • The system demonstrated lower specificity and positive predictive values, leading to numerous false positives.
  • Performance was less reliable for predicting less serious forms of ROP.

Conclusions:

  • WinROP is effective in identifying infants unlikely to develop high-risk ROP, potentially reducing screening burdens.
  • The system's current limitations include a high false-positive rate, making it unsuitable for predicting less severe ROP.
  • WinROP's performance aligns with its intended use for high-risk ROP detection in the Czech preterm infant population.
Abstract