Novel Validated RP-HPLC Method for Bendamustine Hydrochloride Based on Ion-pair Chromatography: Application in
Yuvraj Singh1, Anumandla Chandrashekar1, Vivek K Pawar1
1Pharmaceutics Division, CSIR-Central Drug Research Institute , Lucknow 226031, India.
Abstract:
Ion pair chromatography was used for quantifying bendamustine hydrochloride (BH) in its marketed vial. The permissive objective was to investigate time duration for which highly susceptible drug content of the marketed vial remained stable after reconstitution. However, the method could also be used to measure extremely low levels of drug in rat plasma and a pharmacokinetic study was accordingly conducted to further showcase method's applicability. Optimized separation was achieved on C-18 Purospher®STAR (250 mm × 4.6 mm, 5 μm particle size) column. Mobile phase flowing at 1.5 mL/min consisted of 5 mM sodium salt of octane sulfonic acid dissolved in methanol, water and glacial acetic acid (55:45:0.075) maintained at pH 6. Detection was carried out at 233 nm with BH eluting after 7.8 min. Validation parameters were determined as per ICH guidelines. Limit of detection and limit of quantification were found to be 0.1 µg/mL and 0.33 µg/mL, respectively. The recoveries were 98-102% in bulk and 85-91% in plasma. The developed method was specific for BH, and utilized for assessing its short-term stability in physiologic solvents and forced degradation products in acid, base, oxidative, light and temperature induced stress environments.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
10:33Development of Inhibitors of Protein-protein Interactions through REPLACE: Application to the Design and Development Non-ATP Competitive CDK Inhibitors
Published on: October 26, 2015
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Affinity Chromatography