Evaluation of Blood Lactate and Plasma Insulin During High-intensity Exercise by Antecubital Vein Catheterization
Published on: May 18, 2018
The Effect of Inadequate Presample Blood Volume Withdrawal from Intravenous Catheter and Extension Sets on Measured
F J Marqués1, S Higgins1, R Chapuis1
1Department of Large Animal Clinical Sciences, Western College of Veterinary Medicine, University of Saskatchewan, Saskatoon, SK, Canada.
Background:
Circulating l-lactate concentration is commonly measured in hospitalized horses by sampling from indwelling intravenous (IV) catheters. However, there are no published evidence-based recommendations to prevent contamination by lactated Ringer's solution (LRS).
Hypothesis:
Withdrawing 10 mL of blood from the LRS-containing extension set connected to the IV catheter before obtaining the sample for analysis should be adequate to obtain accurate measurement of blood lactate concentration (BLC).
Animals:
Thirty-three adult hospitalized horses receiving constant rate infusion of LRS.
Methods:
Immediately after disconnecting the LRS, 5 sequential 5 mL blood samples were obtained by aspiration from an extension set connected to an indwelling IV catheter, followed by 3 samples collected by direct venipuncture of the contralateral jugular vein. Samples were analyzed with 1 portable blood lactate analyzer. A linear mixed model was used to examine differences in lactate concentrations among samples collected from the catheter and by direct venipuncture.
Results:
After considering differences in age, breed, sex, and reason for hospitalization, BLCs were higher (P < .001) in the first and second 5 mL samples collected through the extension set/catheter than in all other extension set/catheter samples or the direct venipuncture samples. The largest difference observed between the third and subsequent catheter or venipuncture samples was 0.34 mmol/L with an upper 95% CI of 1.12 mmol/L.
Conclusions And Clinical Importance:
Withdrawing 15 mL of blood from a LRS-containing extension set connected to an IV catheter (5.9 mL total volume capacity) before obtaining the sample for blood lactate analysis is suggested to optimize accuracy of BLC measurements.