Lead isotope ratios in lichen samples evaluated by ICP-ToF-MS to assess possible atmospheric pollution sources in

Alfredo Montero Alvarez1, Juan R Estévez Alvarez1, Clístenes Williams Araújo do Nascimento2

  • 1Center of Technological Applications and Nuclear Development, Calle 30 N° 502, Miramar, Playa, Havana, Cuba.

Related Concept Videos

Mass Spectrometry: Isotope Effect01:13

Mass Spectrometry: Isotope Effect

Most elements exist in nature as a mixture of isotopes. The isotopes differ in weight due to their respective number of neutrons. The molecular weight of a molecule is different depending on the specific isotope of its elements involved. As a result, the mass spectrum of the molecule exhibits peaks from the same fragment at multiple positions. The positions of these mass signals depend on the mass differences between isotopes. Furthermore, the intensity of these signals is dependent on the...
4.7K
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences01:20

Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences

Inductively coupled plasma–mass spectrometry (ICP–MS) is a highly selective and sensitive technique for accurate elemental analysis. Though the analysis of ICP–MS mass spectra is comparatively straightforward, it is affected by spectroscopic and non-spectroscopic interferences. Spectroscopic interferences arise when the plasma contains ionic species with an m/z value the same as the analyte ion. Spectroscopic interference can be categorized as isobaric, polyatomic ions, and...
1.5K
Radioactive Decay and Radiometric Dating02:48

Radioactive Decay and Radiometric Dating

Radioactivity is a spontaneous disintegration of an unstable nuclide and is a random process, as all the nuclei in the sample do not decay simultaneously. The number of disintegrations per unit time is called the activity (A), which is directly proportional to the number of nuclei in the sample. The decay constant (λ) is an average probability of decay per nucleus in unit time.
39.2K
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview01:19

Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

In inductively coupled plasma–mass spectrometry (ICP–MS), an inductively coupled plasma (ICP) torch is used as an atomizer and ionizer. Solid samples are dissolved and volatilized before being introduced into the high-temperature argon plasma, while solution samples are nebulized and passed through the high-temperature argon plasma. Plasma dissociates the analytes and ionizes their component atoms to form a mixture of positive ions and molecular species. The positive ions are then...
2.4K